All Data Dump · Roland D-50

SysEx #1403

half-dump origial file name was BASS_01.syx

Uploaded by andrea · 30 downloads

Manufacturer
Roland · 41
Size
14,896 bytes
Messages
56
Checksum
OK

Structure

Message 1 of 56
Offset Bytes Meaning
0 F0 Start of exclusive
1 41 Manufacturer
2 00 Device ID
3 14 Model ID
4 12 Command Data set (DT1)
5–263 … Data 259 bytes
264 33 Checksum correct
265 F7 End of exclusive

Offsets are counted from the beginning of the file, starting at 0.

Messages in this file

# Offset Length Model ID Checksum
1 0 266 14 OK
2 266 266 14 OK
3 532 266 14 OK
4 798 266 14 OK
5 1064 266 14 OK
6 1330 266 14 OK
7 1596 266 14 OK
8 1862 266 14 OK
9 2128 266 14 OK
10 2394 266 14 OK
11 2660 266 14 OK
12 2926 266 14 OK
13 3192 266 14 OK
14 3458 266 14 OK
15 3724 266 14 OK
16 3990 266 14 OK
17 4256 266 14 OK
18 4522 266 14 OK
19 4788 266 14 OK
20 5054 266 14 OK
21 5320 266 14 OK
22 5586 266 14 OK
23 5852 266 14 OK
24 6118 266 14 OK
25 6384 266 14 OK
26 6650 266 14 OK
27 6916 266 14 OK
28 7182 266 14 OK
29 7448 266 14 OK
30 7714 266 14 OK
31 7980 266 14 OK
32 8246 266 14 OK
33 8512 266 14 OK
34 8778 266 14 OK
35 9044 266 14 OK
36 9310 266 14 OK
37 9576 266 14 OK
38 9842 266 14 OK
39 10108 266 14 OK
40 10374 266 14 OK
41 10640 266 14 OK
42 10906 266 14 OK
43 11172 266 14 OK
44 11438 266 14 OK
45 11704 266 14 OK
46 11970 266 14 OK
47 12236 266 14 OK
48 12502 266 14 OK
49 12768 266 14 OK
50 13034 266 14 OK

Only the first 50 messages are listed.

Hex view

14,896 bytes · 16 per row
00000000 F0 41 00 14 12 02 00 00 30 38 0B 03 00 01 00 04 .A......08......
00000010 08 00 00 00 00 2C 02 0D 0B 0E 42 00 00 04 00 2B .....,....B....+
00000020 09 4B 36 13 20 1F 15 00 00 00 07 64 41 5F 03 00 .K6. ......dA_..
00000030 4E 36 30 4D 64 1D 12 00 00 00 00 00 00 07 00 00 N60Md...........
00000040 00 00 00 00 00 00 00 00 18 39 0B 00 00 01 00 48 .........9.....H
00000050 09 0E 00 00 0E 2E 00 07 00 0E 29 00 02 01 00 0E ..........).....
00000060 33 00 4C 64 00 00 3D 00 00 00 07 64 53 5F 03 00 3.Ld..=....dS_..
00000070 39 30 2E 31 64 18 0E 00 00 00 01 00 00 07 00 00 90.1d...........
00000080 00 00 00 00 00 00 00 00 10 01 00 04 05 03 0F 04 ................
00000090 05 12 02 00 00 00 15 14 00 30 32 32 32 30 00 00 .........02220..
000000A0 00 00 49 00 00 00 00 00 00 00 00 00 00 08 13 14 ..I.............
000000B0 05 0F 07 34 34 30 03 32 00 00 00 00 00 00 00 00 ...440.2........
000000C0 00 00 00 00 00 00 00 00 00 29 0F 03 00 02 00 00 .........)......
000000D0 5D 07 02 00 07 10 00 05 00 07 00 1D 00 02 00 00 ]...............
000000E0 51 4B 49 64 4F 19 0F 00 00 00 08 64 3F 00 0C 00 QKIdO......d?...
000000F0 32 47 4A 36 64 52 28 00 00 00 02 04 00 07 00 00 2GJ6dR(.........
… 14,624 bytes not shown
00003A20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 17 F7 ................
F0 header and end 42 52 patch name 5E checksum 31 63 dataShow all bytes

Comments

0

Sign in to write a comment.

← All SysEx messages for the Roland D-50

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.