All Data Dump · Roland D-50

SysEx #1421

half-dump origial file name was STR_03.syx

Uploaded by andrea · 27 downloads

Manufacturer
Roland · 41
Size
14,896 bytes
Messages
56
Checksum
OK

Structure

Message 1 of 56
Offset Bytes Meaning
0 F0 Start of exclusive
1 41 Manufacturer
2 00 Device ID
3 14 Model ID
4 12 Command Data set (DT1)
5–263 … Data 259 bytes
264 01 Checksum correct
265 F7 End of exclusive

Offsets are counted from the beginning of the file, starting at 0.

Messages in this file

# Offset Length Model ID Checksum
1 0 266 14 OK
2 266 266 14 OK
3 532 266 14 OK
4 798 266 14 OK
5 1064 266 14 OK
6 1330 266 14 OK
7 1596 266 14 OK
8 1862 266 14 OK
9 2128 266 14 OK
10 2394 266 14 OK
11 2660 266 14 OK
12 2926 266 14 OK
13 3192 266 14 OK
14 3458 266 14 OK
15 3724 266 14 OK
16 3990 266 14 OK
17 4256 266 14 OK
18 4522 266 14 OK
19 4788 266 14 OK
20 5054 266 14 OK
21 5320 266 14 OK
22 5586 266 14 OK
23 5852 266 14 OK
24 6118 266 14 OK
25 6384 266 14 OK
26 6650 266 14 OK
27 6916 266 14 OK
28 7182 266 14 OK
29 7448 266 14 OK
30 7714 266 14 OK
31 7980 266 14 OK
32 8246 266 14 OK
33 8512 266 14 OK
34 8778 266 14 OK
35 9044 266 14 OK
36 9310 266 14 OK
37 9576 266 14 OK
38 9842 266 14 OK
39 10108 266 14 OK
40 10374 266 14 OK
41 10640 266 14 OK
42 10906 266 14 OK
43 11172 266 14 OK
44 11438 266 14 OK
45 11704 266 14 OK
46 11970 266 14 OK
47 12236 266 14 OK
48 12502 266 14 OK
49 12768 266 14 OK
50 13034 266 14 OK

Only the first 50 messages are listed.

Hex view

14,896 bytes · 16 per row
00000000 F0 41 00 14 12 02 00 00 0C 2D 0B 01 00 01 01 2D .A.......-.....-
00000010 19 07 00 00 00 30 00 0B 70 07 64 64 00 00 00 20 .....0..p.dd...
00000020 55 3D 59 64 2B 00 00 00 02 00 0A 27 37 2A 09 00 U=Yd+......'7*..
00000030 00 64 64 40 00 64 64 64 00 00 00 00 00 07 00 00 .dd@.ddd........
00000040 00 00 00 00 00 00 00 00 24 37 0B 01 00 01 00 07 ........$7......
00000050 5B 07 00 00 0E 30 1E 05 70 07 27 33 03 00 00 24 [....0..p.'3...$
00000060 55 3D 59 64 2A 00 00 00 04 00 08 64 33 35 09 00 U=Yd*......d35..
00000070 20 23 22 3B 00 44 60 62 00 01 00 00 00 07 00 00 #";.D`b........
00000080 00 00 00 00 00 00 00 00 06 0C 15 14 05 00 36 00 ..............6.
00000090 00 00 02 00 00 08 00 00 00 35 32 2C 32 35 07 16 .........52,25..
000000A0 13 00 4C 2B 00 00 0A 00 01 00 54 00 00 00 04 00 ..L+......T.....
000000B0 00 08 00 32 33 2D 03 15 00 00 00 00 00 00 00 00 ...23-..........
000000C0 00 00 00 00 00 00 00 00 24 2C 0B 01 00 01 00 07 ........$,......
000000D0 13 07 00 00 0E 2F 14 05 70 07 60 33 03 00 00 14 ...../..p.`3....
000000E0 09 0E 59 64 64 3A 1C 00 04 00 08 64 33 35 0C 00 ..Ydd:.....d35..
000000F0 20 23 22 38 00 44 60 62 00 04 00 00 00 07 00 00 #"8.D`b........
… 14,624 bytes not shown
00003A20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 67 F7 ..............g.
F0 header and end 42 52 patch name 5E checksum 31 63 dataShow all bytes

Comments

0

Sign in to write a comment.

← All SysEx messages for the Roland D-50

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.