All Data Dump · Roland D-50

SysEx #1985

Uploaded by migueltrevi · 35 downloads

Manufacturer
Roland · 41
Size
36,048 bytes
Messages
136
Checksum
OK

Structure

Message 1 of 136
Offset Bytes Meaning
0 F0 Start of exclusive
1 41 Manufacturer
2 00 Device ID
3 14 Model ID
4 12 Command Data set (DT1)
5–263 … Data 259 bytes
264 2A Checksum correct
265 F7 End of exclusive

Offsets are counted from the beginning of the file, starting at 0.

Messages in this file

# Offset Length Model ID Checksum
1 0 266 14 OK
2 266 266 14 OK
3 532 266 14 OK
4 798 266 14 OK
5 1064 266 14 OK
6 1330 266 14 OK
7 1596 266 14 OK
8 1862 266 14 OK
9 2128 266 14 OK
10 2394 266 14 OK
11 2660 266 14 OK
12 2926 266 14 OK
13 3192 266 14 OK
14 3458 266 14 OK
15 3724 266 14 OK
16 3990 266 14 OK
17 4256 266 14 OK
18 4522 266 14 OK
19 4788 266 14 OK
20 5054 266 14 OK
21 5320 266 14 OK
22 5586 266 14 OK
23 5852 266 14 OK
24 6118 266 14 OK
25 6384 266 14 OK
26 6650 266 14 OK
27 6916 266 14 OK
28 7182 266 14 OK
29 7448 266 14 OK
30 7714 266 14 OK
31 7980 266 14 OK
32 8246 266 14 OK
33 8512 266 14 OK
34 8778 266 14 OK
35 9044 266 14 OK
36 9310 266 14 OK
37 9576 266 14 OK
38 9842 266 14 OK
39 10108 266 14 OK
40 10374 266 14 OK
41 10640 266 14 OK
42 10906 266 14 OK
43 11172 266 14 OK
44 11438 266 14 OK
45 11704 266 14 OK
46 11970 266 14 OK
47 12236 266 14 OK
48 12502 266 14 OK
49 12768 266 14 OK
50 13034 266 14 OK

Only the first 50 messages are listed.

Hex view

36,048 bytes · 16 per row
00000000 F0 41 00 14 12 02 00 00 24 32 0F 01 00 01 01 31 .A......$2.....1
00000010 00 07 00 00 07 64 00 0B 00 07 64 39 00 00 00 00 .....d....d9....
00000020 00 00 3F 64 64 64 64 00 00 00 00 64 51 00 0C 15 ..?dddd....dQ...
00000030 00 00 00 42 64 64 64 64 00 00 00 00 00 07 00 00 ...Bdddd........
00000040 00 00 00 00 00 00 00 00 24 32 06 02 00 01 01 43 ........$2.....C
00000050 00 07 00 00 07 64 00 0B 00 07 64 00 00 00 01 00 .....d....d.....
00000060 00 00 3F 3A 64 64 64 00 00 00 00 4B 32 00 0C 12 ..?:ddd....K2...
00000070 39 00 00 42 64 59 55 4F 00 00 02 00 00 07 00 00 9..BdYUO........
00000080 00 00 00 00 00 00 00 00 08 1F 1B 30 1F 28 00 35 ...........0.(.5
00000090 00 00 05 00 00 14 14 14 14 32 32 32 32 32 00 16 .........22222..
000000A0 0F 00 4B 00 00 00 00 00 00 00 00 00 00 09 0E 15 ..K.............
000000B0 08 10 00 2E 4A 64 03 32 00 00 00 00 00 00 00 00 ....Jd.2........
000000C0 00 00 00 00 00 00 00 00 0C 32 0F 01 00 01 01 0C .........2......
000000D0 00 07 00 00 07 64 00 0C 00 07 64 00 00 00 00 00 .....d....d.....
000000E0 00 00 3F 64 64 64 64 00 00 00 00 64 49 3F 08 00 ..?dddd....dI?..
000000F0 34 00 00 42 64 00 00 00 00 00 00 00 00 07 00 00 4..Bd...........
… 35,776 bytes not shown
00008CC0 00 01 00 01 08 01 0F 0F 07 01 0A 0D 0E 01 0F F7 ................
F0 header and end 42 52 patch name 5E checksum 31 63 dataShow all bytes

Comments

0

Sign in to write a comment.

← All SysEx messages for the Roland D-50

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.