The Behringer B-Control Fader BCF2000 is a USB and MIDI control surface built around eight motorized 100 mm faders. When a preset is recalled the faders slide to their stored positions, and when the connected software or instrument sends parameter feedback they follow its values. Above them sit eight push encoders with LED rings, switchable across four encoder groups for 64 functions per preset, plus assignable keys, system keys and a four-digit LED display. The unit stores 32 presets. It works with a computer as a class-compliant USB MIDI device, where it can also act as a MIDI interface, or stand-alone through its MIDI In, Out A and Out B/Thru sockets, in four USB and four stand-alone operating modes. A footswitch input and a foot controller input complete it, and fader motors can be switched off temporarily from a key. It shares its manual and menus with the encoder-based BCR2000. Behringer now lists it as a legacy product. The BCF2000 sends its presets as System Exclusive dumps, either the current preset with all its control assignments or the whole memory of 32 presets. Dumps are tied to a device ID from 1 to 16, so several units can share one MIDI setup.
SysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 00 20 32
Receiving a dump
No settings are needed to receive a dump, but the device ID (global setup, push encoder 5, 1 to 16) must match the one the dump was sent with. A single preset goes to a temporary memory: press STORE and choose a preset slot to keep it. An All dump overwrites the whole memory at once.
Sending a dump from the instrument
1. Hold EDIT and press STORE to open the global setup menu. 2. Turn push encoder 6 to Single (current preset) or All (all 32 presets). 3. Press encoder 6 once to start the dump; EXIT cancels it. Shortcut: hold EDIT and press PRESET right to send the whole current preset.
SysEx pitfalls
An All dump sent to the unit overwrites its entire memory without confirmation or safety copy. Dumps are received only at the device ID they were sent to. MIDI Data Interval (global setup, encoder 8, in milliseconds) sets the transmission rate of SysEx dumps.
Source: Behringer, B-Control Fader BCF2000 / Rotary BCR2000 User Manual (EN), p. 6, 18-19 ↗
Specifications
- Memory
- 32 presets
- Keyboard / format
- Desktop controller: 8 motorized 100 mm faders, 8 push encoders with LED rings, 20 keys and 10 system keys, 4-digit LED display
- MIDI
- MIDI In, Out A, Out B/Thru (5-pin DIN); USB MIDI, class compliant
Known issues and maintenance
Fader motors can be disengaged while a key assigned to them is held (Motor Off function). Panic Reset: hold EDIT and press EXIT to return the most important MIDI data to factory settings.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Behringer, B-Control Fader BCF2000 / Rotary BCR2000 User Manual (English) ↗ — SysEx dumps, device ID and data interval p. 18-19, faders and controls p. 8, Motor Off p. 19, operating modes p. 9-12, specifications p. 22
- Behringer product page BCF2000 (0808-AAB) ↗ — Legacy status, manuals, firmware, B-Control Edit and BCFview downloads