Clavia Nord Modular G2

Photo: Mac Rutan from Oviedo, FL, U.S.A. · CC BY-SA 2.0 ↗

Clavia · Synthesizer · 2004

Clavia Nord Modular G2

The Clavia Nord Modular G2 is the second generation of Clavia's virtual analog modular synthesizer, made from 2004 to 2007 in three versions: the G2 with a three-octave keyboard, the larger G2X with five octaves and the voice expansion fitted, and the G2 Engine, a 1U rack unit programmed only from the computer. Patches are built in the G2 Editor by placing and cabling modules on screen; they then run on the synth's own DSP and can be played without the computer. Polyphony depends on how much processing a patch needs, up to 32 voices, and four slots let four patches play together as a Performance. The synth stores up to 4,096 patches and 1,024 performances in a 6 MB file system, so the real number depends on patch size. Unlike the first Nord Modular, the G2 has a published System Exclusive implementation on its ordinary MIDI ports. On the G2 and G2X, SHIFT + SYSTEM (Dump One) sends the patch in the focused slot, or the whole performance, as a dump that a sequencer can record; the Engine does the same from the Editor. A dump is split into blocks with a checksum, about 5 kB for a patch and nearly 20 kB for a performance, and a patch sent back is loaded into the current slot. These dumps are a different format from the Editor's .pch2 and .prf2 files.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
33
Model ID
0A
Default device ID
MIDI SysEx ID in the System menu, 1-16 or All (00-0F or 7F in the message)

Receiving a dump

1. In the System menu set MIDI SysEx ID to All, or to the ID stored in the dump (1-16). 2. Connect the sequencer's MIDI Out to MIDI IN on the G2. 3. Play back the dump: the patch is loaded as a new patch in the current slot. Store it with Memory Protect off if it must be kept.

Sending a dump from the instrument

G2 and G2X: select the slot (or enter Performance mode) and hold SHIFT while pressing SYSTEM (Dump One). The patch in the focused slot, or the whole performance, is sent from MIDI OUT. G2 Engine: in the Editor choose Setup, Dump One (Ctrl+1) to send the patch in the active slot.

Requesting a dump

Documented in the SysEx specification: message 30 requests the patch in a slot (00-03 = A-D, 04 = active slot), 31 a stored patch by bank (00-1F) and number (00-7F), 38 the loaded performance, 39 a stored performance by bank (00-07) and number, 40 all controller values of a slot.

SysEx pitfalls

Patch dumps (message 20) and performance dumps (28) are split into several SysEx blocks, each with block number, block count, a 16-character name and a checksum of the least 7 bits of the block's bytes. A patch is about 5 kB and a performance nearly 20 kB; at about 3 kB per second a performance takes up to seven seconds. The data are compressed. SysEx dumps are a different format from the Editor's .pch2 and .prf2 files, which only the Editor can use; only a dump made with Dump One can be sent back over MIDI IN.

Source: Nord Modular G2 English User Manual v1.4 Edition 1.4x, pp. 29, 32, 125, 148-153 ↗

Specifications

Produced
2004–2007
Synthesis
Virtual analog modular synthesis on DSP, patches built in the G2 Editor software
Polyphony
Up to 32 voices, depending on patch complexity
Multitimbrality
4 slots (A to D), combined in a Performance
Oscillators
Chosen per patch from the module library
Filter
Chosen per patch from the module library
Memory
32 banks of 128 patch locations and 8 banks of 128 performance locations in a 6 MB file system; capacity depends on patch size
Keyboard / format
G2: 3 octaves with aftertouch; G2X: 5 octaves semi-weighted with aftertouch; G2 Engine: 1U rack module
Outputs
4 line outputs, headphone output; 4 line inputs, microphone input on G2 and G2X
MIDI
MIDI In, Out, Thru; USB 1.1 for the Editor

Known issues and maintenance

Memory Protect is on when the G2 is shipped and must be disabled before storing patches or performances. The legacy Editor does not run on Mac OS X 10.7 or later.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Clavia, Nord Modular G2 English User Manual v1.4 Edition 1.4x ↗ — Models, slots, memory, Dump One, SysEx ID, G2 MIDI System Exclusive Specification, MIDI implementation chart
  2. Nord Keyboards: Nord Modular G2 (legacy products) ↗ — Production 2004-2007, models, polyphony, inputs and outputs, MIDI and USB, memory
  3. Nord Keyboards: Nord Modular G2 downloads (legacy products) ↗ — OS 1.62, Editor demo, manuals, Mac OS compatibility note

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.