no image yet
Clavia · Synthesizer · 2005

Clavia Nord Stage

The Clavia Nord Stage is a stage keyboard made from 2005 to 2008 in three versions: the Nord Stage 88 and 76 with weighted hammer-action keys, and the lighter Nord Stage Compact. It brings together three instruments: an organ section modelling a tonewheel B3, a Vox Continental and a Farfisa, a piano section playing sampled acoustic and electric pianos, Clavinet and electric grand, and a synth section with analog-style waveforms, FM and wavetables. Everything can be doubled: two complete panels, A and B, each hold a full set of instruments and effects, so the Stage can layer and split sounds or play two organ manuals at once. Programs live in flash memory, 126 locations in 21 pages of six plus two live buffers, and the synth section has its own 300 sound memories in three categories. Clavia's product page lists MIPA awards for best stage piano from 2006 to 2008. Over MIDI the Stage sends and receives System Exclusive dumps of a single program or of all programs, of synth sounds one at a time, by category or all together, and snapshots of the panel controllers. Clavia published the dump format in a separate SysEx guide. Piano samples never travel as SysEx: a program dump carries the piano settings only, and samples, programs and full backups are handled over USB by the Nord Sound Manager in its own file formats.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
33
Model ID
0B
Default device ID
Instrument SysEx ID in the MIDI menu, 1-16 or All; factory setting All

Receiving a dump

1. In the MIDI menu (SHIFT + MIDI) set Instrument SysEx ID to All, or to the ID stored in the file. 2. Connect the sender's MIDI Out to MIDI IN on the Nord Stage. 3. Start the transmission on the sending device. An All dump replaces all programs; a single program goes to the selected program location and must then be stored with STORE (Memory Protect off).

Sending a dump from the instrument

Programs: press SHIFT + MIDI, select Dump Program Source with the PAGE buttons, choose One or All with the value dial and press STORE. For a quick dump of the current program press SHIFT + DUMP ONE (the PANEL A button). Synth sounds: SHIFT + MIDI, select Dump Synth Sound, choose the active panel's sound, one category (Synth, Pad, Bass) or All, and press STORE. Controller snapshot: SHIFT + MIDI, Send MIDI Ctrl, choose Panel A or B and press STORE.

Requesting a dump

The SysEx guide documents requests: message 38 for the program edit buffer, 39 for a program by bank (00-14) and program (00-05), 31 for a synth sound by bank (00 Bass, 01 Pad, 02 Synth) and number (00-62). Requests for the synth sound edit buffer are not supported.

SysEx pitfalls

Program dumps (message 28 edit buffer, 29 stored program) carry 471 data bytes and synth sound dumps (21) 45 bytes, each closed by a 7-bit checksum of all preceding bytes. Piano samples are not included: when a piano program is sent back, the same piano must already be in the instrument or another piano is used. Sound Manager files (.nspg, .nss, .nsb) are not SysEx.

Source: Nord Stage English SysEx Guide (OS V2.16); Nord Stage User Manual v2.0x, pp. 76-77; Nord Stage EX User Manual v6.x, pp. 69, 88-89 ↗

Specifications

Produced
2005–2008
Synthesis
Modelled tonewheel and combo organs, sampled pianos, and a synth with analog-style waveforms, 2- and 3-operator FM and wavetables
Polyphony
Synth 16 voices, piano 40 to 60 voices, organ full polyphony
Multitimbrality
Two panels (A and B), each with organ, piano and synth sections; each instrument section is 2-part
Memory
126 programs (21 pages of 6) plus 2 live buffers; 300 synth sounds in 3 categories (Bass, Pad, Synth)
Keyboard / format
88 or 76 weighted hammer-action keys; Compact with medium weighted keys; aftertouch; up to 3 split zones
Outputs
4 assignable unbalanced line outputs, stereo headphone output
MIDI
MIDI In, MIDI Out; USB type B

Known issues and maintenance

Memory Protect is on when the instrument leaves the factory and must be switched off before storing programs. Programs, OS and piano samples are kept in flash memory and no backup battery is required.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Clavia, Nord Stage English SysEx Guide (OS V2.16) ↗ — Message formats, model ID 0B, SysEx ID range, data sizes and checksum
  2. Clavia, Nord Stage Portuguese User Manual v2.0x ↗ — Manual of the original Nord Stage: MIDI menu, Instrument ID default All, dump and receive procedures
  3. Clavia, Nord Stage EX English User Manual v6.x Edition 6.0 ↗ — English wording of the same dump procedures, Memory Protect, flash memory, Nord Sound Manager and its file formats
  4. Nord Keyboards: Nord Stage specifications (legacy products) ↗ — Polyphony, memory, keyboards, outputs, MIDI and USB, dimensions
  5. Nord Keyboards: Nord Stage (legacy products) ↗ — Production 2005-2008, models, sections, MIPA awards
  6. Nord Keyboards: About us ↗ — Introduced in 2005

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.