no image yet
E-MU Systems · Drum Machine · 1987

E-MU Systems SP-1200

The E-MU SP-1200 is a sampling drum machine and sequencer from 1987. It records 12-bit samples at a fixed 26.04 kHz, with ten seconds of sampling time shared among 32 user sounds. Eight pads, each with its own fader, play the sounds, and eight individual outputs carry them to a mixer. The sequencer holds 100 patterns, called segments, and 100 songs, and can follow MIDI clock or SMPTE. Data is saved on 3.5-inch floppy disks. Its System Exclusive use is limited to sounds. With SPECIAL 23 it sends a single sound using the MMA MIDI Sample Dump Standard, and with SPECIAL 24 it requests one from another device. The owner's manual describes no MIDI dump of sequences, songs or settings.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
18

Receiving a dump

1. Connect the SP-1200 MIDI OUT to the other device's MIDI IN and the other device's MIDI OUT to the SP-1200 MIDI IN. 2. Press SPECIAL 24; the display asks to select a sound. 3. Press the pad of the destination sound: the SP-1200 sends a Dump Request for that sound number and receives the dump. 4. When the display confirms the transfer, press ENTER.

Sending a dump from the instrument

1. Connect MIDI IN and OUT in both directions. 2. Press SPECIAL 23; the display asks to select a sound. 3. Press the pad of the sound to send; it goes out as a MIDI Sample Dump. 4. When the display confirms the transfer, press ENTER.

Requesting a dump

In SPECIAL 24 the SP-1200 itself sends an MMA Sample Dump Request for the selected sound number to the external device.

SysEx pitfalls

Only single sounds are transferred, using the MMA MIDI Sample Dump Standard; the other device must support it. A received sound can be no larger than the sound already in the chosen location, and the request is sent only if that location is not empty. Only the 12 most significant bits of each word are used. A failed transfer shows Sound Dump Bad, Press Enter.

Source: E-MU SP-1200 Owner's Manual (PN FI 332 Rev. E, 1987), Appendix G (Special Functions 23 and 24) and Appendix J (MIDI implementation)

Specifications

Synthesis
12-bit sample playback at 26.04 kHz
Memory
32 user sounds, 10 seconds total sampling time; 100 segments and 100 songs; storage on 3.5-inch DS/DD floppy
Keyboard / format
8 pads, each with a fader
Outputs
8 individual outputs plus a mono mix output

Known issues and maintenance

Memory is lost at power-off: sounds, segments and songs must be saved to floppy disk.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. E-MU SP-1200 Owner's Manual, PN FI 332 Rev. E, 1987 (Internet Archive copy, linked by Rossum Electro-Music) — Sound memory, segments and songs, outputs, disk, MIDI Sample Dump transmit and receive, MIDI implementation chart
  2. David Mellor, "E-mu SP1200", Sound On Sound, October 1987 ↗ — Review: UK price, 12-bit 26 kHz, 32 samples, 8 pads with faders, outputs, sync, verdict

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.