The Ensoniq KS-32 is a weighted-action keyboard that Ensoniq called a Weighted Action MIDI Studio. Its service manual describes it as a close relative of the SQ-2 32 Voice: the main board, keypad and display board and keyboard differ, but the transformer, transformer adapter board and mono pressure board are shared, and the two are debugged the same way. The keyboard has mono pressure response. The instrument holds internal sounds, presets and sequences in battery-backed RAM; reinitialising restores the internal sounds from ROM and erases presets and sequences. Like the SQ family it stores sounds and sequences on credit-card memory cards. Over System Exclusive the KS-32 sends its internal sound banks 0 to 7 (80 sounds) as one message and the whole sequencer memory, 70 sequences and 30 songs, as another. Reception needs no front-panel command once System Exclusive is enabled on the System-MIDI page.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
0F

Receiving a dump

1. Open the System-MIDI page, screen 8. 2. Set System Excl=ON. Reception then starts automatically when the dump arrives.

Sending a dump from the instrument

Sounds: 1. Connect KS-32 MIDI Out to the recorder's MIDI In. 2. Press Edit Sound, then Bank 9 (Store Sounds): Press ENTER to Store Sounds. 3. Press Enter-Save and choose Storage Type=MIDI SYS-EX. 4. Choose Operation=SAVE INT TO MIDI and press Enter-Save. Sequences: same from Edit Seq/Preset, choosing SAVE ALL SEQUENCES.

SysEx pitfalls

The internal sound dump contains all 80 internal sounds; the sequence dump contains the whole sequencer memory (70 sequences and 30 songs).

Source: Ensoniq KS-32 Service Manual, P/N 9312001501-B, October 1993, printed p. 25

Specifications

Memory
80 internal sounds in banks 0-7; 70 sequences and 30 songs; memory cards
Keyboard / format
Weighted action with mono pressure
MIDI
MIDI In and Out (Out used to send dumps)

Known issues and maintenance

Bad card data, a bad Sys-Ex transfer or a power glitch can scramble the RAM; reinitialising (Edit Seq/Preset, hold Bank 9 and press Screen 9, then Yes) erases presets and sequences. A Battery low message can appear after a glitch; check BAT= (125 to 205) in the test mode.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Ensoniq KS-32 Service Manual, P/N 9312001501-B, October 1993 (third-party copy on ManualsLib) — Relation to the SQ-2 32 Voice, reinitialisation, software version, battery test, saving to MIDI Sys-Ex and receiving Sys-Ex data, memory cards