Korg · Sampler

Korg Electribe ESX-1

The Korg Electribe ESX-1 (Electribe SX) is the sampling member of Korg's Electribe range, built around the same layout and step sequencer as the EMX-1. Instead of synthesis it plays the user's own samples: the internal memory holds up to 384 samples (256 mono and 128 stereo) for a total of 285 seconds of mono sound, recorded at 44.1 kHz through the stereo audio input or loaded as WAV or AIFF files from a SmartMedia card. Nine drum parts, two monophonic keyboard parts and the stretch and slice parts play the samples, and three effect processors and two 12AX7 valves on the output complete the sound path. Patterns of up to 128 steps per part are kept in 256 memories, and 64 songs chain them together. Sound On Sound (March 2004) praised its ease of use and its sound, called it a worthy partner to the EMX-1, and found loading single samples from a card awkward. The ESX-1 System Exclusive dumps carry a bank of 64 patterns, all songs or the global settings, and are sent from the MIDI dump page or on request; samples are not among the dump choices and are saved on SmartMedia instead. Memory protect is on when the unit leaves the factory and must be turned off before a dump can be received.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
42
Model ID
71
Default device ID
Global MIDI channel, which is the channel of keyboard part 1

Receiving a dump

1. Press GLOBAL, select Protect and set it to Off (it is On at the factory). 2. Set the global MIDI channel to the channel used when the dump was saved. 3. In Global mode hold SHIFT and press step key 15 (MIDI UTILITY). 4. Turn the dial to Dump and press key 15: the display shows MIDIDump. 5. Send the file from the computer. Do not touch the keys; the ESX-1 needs up to ten seconds to write each dump into memory.

Sending a dump from the instrument

1. Press GLOBAL, hold SHIFT and press step key 15 (MIDI UTILITY). 2. Turn the dial to Dump and press key 15: the display shows MIDIDump. 3. Turn the dial to choose PtBnkA, PtBnkB, PtBnkC, PtBnkD (64 patterns each), AllSng (all songs) or Global. 4. Press key 15 again to transmit. STOP/CANCEL cancels before transmission starts.

Requesting a dump

Requests, with g = global MIDI channel minus 1: Current pattern: F0 42 3g 71 10 F7 (answer 40). Pattern bank: F0 42 3g 71 1C bb F7, bb 0-3 = bank A-D (answer 4C). Current song: F0 42 3g 71 0A F7 (answer 58). All songs: F0 42 3g 71 0B F7 (answer 57). Global: F0 42 3g 71 0E F7 (answer 51).

SysEx pitfalls

Samples cannot be dumped by MIDI: the dump menu offers only patterns, songs and global data. Dumps are received only when the sequencer is stopped or on the MIDI dump page, and with Protect On only in Global mode. After each received dump the unit answers 23 (Data Load Completed) or 24 (Data Load Error) and takes up to ten seconds to write; leave a pause between dumps. Data is 8-bit and packed 7-to-8 for MIDI; one pattern is 4,280 bytes before packing, a bank 273,920 bytes and the global data 192 bytes.

Source: Korg ESX-1 Owner's Manual pp. 92, 95; ESX-1 MIDI Implementation v1.1 (2003) ↗

Specifications

Synthesis
Sample playback (44.1 kHz user samples) with filter, amplifier and effects per part
Polyphony
Each of the 2 keyboard parts is monophonic
Multitimbrality
16 parts: 2 keyboard, 9 drum, drum accent, stretch, slice, audio in, accent
Oscillators
User samples: up to 384 (256 mono, 128 stereo), 285 seconds mono in total
Filter
Multimode low-pass, high-pass and band-pass per part
Memory
256 patterns, 64 songs; SmartMedia card slot
Keyboard / format
Tabletop unit with 16 step keys, ribbon controller and arpeggiator slider
Outputs
L/MONO and R, individual outputs 3 and 4, headphones; stereo audio input
MIDI
MIDI In, Out, Thru

Known issues and maintenance

Memory protect is on at the factory: patterns and songs cannot be written and dumps cannot be received outside Global mode until Protect is set to Off. Initializing the user data (power on holding SOLO and WRITE/RENAME, then PLAY/PAUSE) erases all patterns, songs and samples. The vacuum tubes are not user serviceable. Korg warns that some USB-MIDI interfaces cannot pass the ESX-1's exclusive messages.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Korg ESX-1 Owner's Manual (E2, 2003) ↗ — Features, sample memory, monophonic keyboard parts, memory protect, dump procedures, SysEx format, initialization, specifications
  2. Korg ESX-1 MIDI Implementation, version 1.1 (9 September 2003) ↗ — Exclusive header with model ID 71, device inquiry, dump and request messages, table sizes, receive conditions
  3. Korg USA: ELECTRIBE-SX downloads ↗ — List of manuals, MIDI implementation and system updater; product marked sold out
  4. Derek Johnson, "Korg ESX1", Sound On Sound, March 2004 ↗ — Review: price, sample memory, 16-bit 44.1 kHz sampling, 12 dB filter, pros and cons