no image yet
Korg · Synthesizer

Korg EX-8000

The Korg EX-8000 is the rack-mount, keyboardless counterpart of the DW-8000 synthesizer. It plays eight voices, each built from two digital oscillators that choose among 16 waveforms, plus white noise, followed by a filter and an amplifier with their own six-stage envelopes. Like the DW-8000 it stores a digital delay setting in every program. Played from a MIDI keyboard it responds to velocity and aftertouch, and its key window parameters restrict it to a range of notes, so that several modules can be split across one keyboard. A prototype was reported in November 1985 as housing the same sound circuitry as the DW-8000, and in February 1986 International Musician called it "a more sophisticated beast" than Korg's earlier EX-800 expander. The EX-8000 holds 64 programs, kept by a rechargeable backup battery and saved to cassette or over MIDI. Its System Exclusive messages use the same ID byte as the DW-8000, and a dump carries one program as 51 bytes of data. The manual gives front-panel procedures, driven by parameter 78, to load one program or all 64 from another EX-8000 or a DW-8000 and to send programs to them; the rear WRITE switch must be on ENABLE while doing so.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

From compatible models

Korg DW-8000 / EX-8000

Related models: DW-8000

The EX-8000 owner's manual describes program transfer between the EX-8000 and the DW-8000 in both directions.

SysEx guide

Manufacturer ID
42
Model ID
03
Default device ID
MIDI channel set with parameter 84 (the n of the format byte 3n)

Receiving a dump

To receive one program from another EX-8000 or a DW-8000 (Single Program Load): 1. Connect MIDI OUT and MIDI IN of the two units in both directions and set the same MIDI channel (parameter 84) on both. 2. Set the WRITE switch to ENABLE. 3. Set parameter 78 to 1. 4. With the number keys enter the number of the program wanted on the other unit. 5. Press WRITE: the program number flashes. 6. Enter the program number that will receive the data. The display shows Good, or Err if the transfer failed (press WRITE and repeat from step 4). 7. Press WRITE: the display returns to normal. 8. Set the WRITE switch back to DISABLE. To receive all 64 programs (All Program Load): WRITE switch on ENABLE, parameter 78 to 2, press WRITE, select program 11, wait for Good, press WRITE, WRITE switch back to DISABLE.

Sending a dump from the instrument

To send one program to a DW-8000 or another EX-8000 (Single Program Save): 1. Connect the two units in both directions on the same MIDI channel. 2. Set the WRITE switch to ENABLE. 3. Set parameter 78 to 3. 4. With the number keys enter the program to send. 5. Press WRITE: the program number flashes. 6. Enter the program number on the other unit that will receive the data. The display shows Good or Err. 7. Press WRITE: the display returns to normal. 8. Set the WRITE switch back to DISABLE.

Requesting a dump

Send a data dump request: F0 42 3n 03 10 F7, where n is the MIDI channel minus one. The EX-8000 answers with a data dump of one program: F0 42 3n 03 40, 51 data bytes, F7.

SysEx pitfalls

One program per dump: a full bank is the same exchange repeated 64 times. System Exclusive messages on a channel different from parameter 84 are ignored, whatever the Omni setting. A write request that cannot be carried out because the WRITE switch is on DISABLE is answered with a write error message; a successful one with write completed (F0 42 3n 03 21 F7). Parameter change messages (function 41) are received only.

Source: Korg EX-8000 Owner's Manual, MIDI section and MIDI Implementation (pp. 52 and 55-62 of the 72-page scan)

Specifications

Synthesis
Digital waveform oscillators (16 waveforms) followed by a filter (VCF) and amplifier (VCA) with envelopes; programmable digital delay
Polyphony
8 voices; key assign modes Poly 1, Poly 2, Unison 1, Unison 2
Oscillators
2 digital oscillators per voice, each with 16 waveforms and 16', 8', 4' octaves; OSC2 interval and detune; white noise; auto bend
Filter
VCF with cutoff, resonance, keyboard tracking, envelope polarity and intensity; dedicated six-stage envelope with velocity sensitivity
Memory
64 programs; tape interface for backup
Keyboard / format
Rack module without keyboard (rack mount adapter supplied)
Outputs
R and L/MONO outputs with HIGH/LOW level switch, headphones
MIDI
MIDI IN, OUT, THRU

Known issues and maintenance

Backup battery. Program memory is kept by a built-in rechargeable backup battery. Korg recommends having it replaced by a dealer or service centre after five years and keeping a copy of the programs on tape. Write switch. Programs can be written, or received over MIDI, only with the WRITE switch on ENABLE; the manual tells the user to return it to DISABLE afterwards.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Korg EX-8000 Owner's Manual — Specifications, backup battery, System Exclusive messages, parameter 78 and the procedures to exchange programs with a DW-8000 or another EX-8000. Read through the OCR of a scan; no official Korg copy found.
  2. Korg DW-8000 Owner's Manual ↗ — The DW-8000 uses the same header (ID 03) and the same 51-byte program dump
  3. Julian Colbeck, "Back to Back", International Musician & Recording World, February 1986 ↗ — The EX-8000 as expander version of the DW-8000: 16 waveforms, delay, velocity response, key window
  4. Simon Trask, "Here In Black & White", Electronics & Music Maker, November 1985 ↗ — EX8000 prototype with the same sound circuitry as the DW-8000, including the delay

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.