Korg M50
The Korg M50 is a music workstation made in 61, 73 and 88-key versions, the largest with Korg's weighted RH3 action. It uses EDS (Enhanced Definition Synthesis), the engine of the more expensive M3, which led Sound On Sound to call it an M3 Lite. Its 256 MB wave ROM holds 1,077 multisamples and 1,609 drum samples, and a voice can use one or two oscillators with two multi-mode filters each, for up to 80 voices in single mode. The M50 combines 16-part Combinations, a 16-track MIDI sequencer, two arpeggiators, a drum track and five insert effects, with a touch screen and an SD card slot for storage. It has no sampling, no aftertouch and no MIDI Thru. Sound On Sound wrote that Korg had raised the standard against which affordable workstations would be judged. Over MIDI or USB the M50 sends System Exclusive dumps of all or single Programs, Combinations, drum kits, arpeggio patterns, global settings, sequencer songs and drum track patterns from the Global mode menu, and these are written straight into the internal memory of the receiving unit. With Enable Exclusive switched on it also answers dump requests from an editor. Songs and samples are not kept when the power is off and must be saved to SD card.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 42
- Model ID
- 00 01 05
- Default device ID
- Global MIDI channel (3n in the header)
Receiving a dump
1. Set the sending device to the M50 global MIDI channel (Global 1-1a); data recorded from another unit needs the same global channel used when it was sent. 2. In Global P1: MIDI check Enable Exclusive (1-2b), or open one of the Dump menu commands of that page: while it is shown, dumps are received regardless of Enable Exclusive. 3. Make sure Memory Protect (Global 0-2b) is off for the data type.
Sending a dump from the instrument
1. Connect MIDI OUT (or USB) to the receiver. 2. Go to Global P1: MIDI. 3. From the page menu choose Dump Program, Dump Combination, Dump Drum Kit, Dump Arpeggio Pattern, Dump Global Setting, Dump Sequencer or Dump Drum Track Pattern. 4. Choose All, Bank or Single as offered, and set To to MIDI OUT or USB. 5. Press OK. The display shows Now Transmitting MIDI Data.
Requesting a dump
If Enable Exclusive is checked, the M50 transmits data in reply to a Dump Request message on the global MIDI channel. Data received this way goes to the edit buffer and must be stored with Write or with a SysEx write request. The full request format is in the separate MIDI Implementation document.
SysEx pitfalls
Dumps sent from the Dump menu are written directly into internal memory, about 1 second per bank; during writing MIDI is not received and Active Sensing stops. When storing dumps in a data filer, do not merge several dumps into one block, or the M50 will not have time to write them on playback. Do not touch the panel during transfer. Memory Protect blocks reception. Samples are not included in any dump.
Specifications
- Synthesis
- EDS (Enhanced Definition Synthesis), sample-based
- Polyphony
- 80 voices max in single mode, 40 in double mode
- Multitimbrality
- 16 timbres in Combination mode, 16 MIDI tracks in Sequencer mode
- Oscillators
- 1 or 2 oscillators per program (Single/Double), 4 velocity zones each; 256 MB ROM, 1,077 multisamples, 1,609 drum samples
- Filter
- Two multi-mode filters per voice (low pass, high pass, band pass, band reject), four routings
- Memory
- 640 user Programs, 512 user Combinations, 48 user drum kits, plus 256 GM2 Programs and 9 GM2 drum programs
- Keyboard / format
- M50-61: 61 keys Natural Touch; M50-73: 73 keys; M50-88: 88 keys RH3 weighted; no aftertouch
- Outputs
- L/MONO and R (1/4 inch unbalanced), headphones
- MIDI
- MIDI IN, MIDI OUT, USB (MIDI)
Known issues and maintenance
Songs, multisamples and samples are lost at power-off unless saved to SD card. Turning the power off while received data is being written can leave the unit unable to start correctly; holding RESET CONTROLS and REALTIME CONTROL at power-on recovers it but initialises the memory.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Korg M50 Parameter Guide (E2) ↗ — Dump commands and procedures, Enable Exclusive, Memory Protect, SysEx header with model ID 00 01 05, inquiry reply member codes, MIDI Implementation chapter
- Korg M50 Owner's Manual (E3) ↗ — Specifications p. 107: EDS, polyphony, ROM, memory, keyboards, outputs, MIDI; data lost at power-off
- Korg USA support downloads: M50 ↗ — Sold-out status, manuals, editor, updater, MIDI Implementation ZIP
- Paul Nagle, "Korg M50", Sound On Sound, October 2008 ↗ — Review: relation to M3, sequencer, SD card, lack of aftertouch and MIDI Thru, verdict