The Korg monologue is a 25-key monophonic analogue synthesizer, announced in November 2016 as a single-voice relative of the minilogue. It has two VCOs with shape control, sync and ring modulation (the second can also produce noise), a two-pole filter followed by a drive circuit, one envelope and one LFO with fast, slow and one-shot modes. A 16-step sequencer stores a pattern in every program and can record the movement of up to four knobs, the OLED display doubles as an oscilloscope, and microtuning offers user scales. It runs on six AA batteries or an optional adapter and came in five colours. Presets and scales were developed with Richard D. James (Aphex Twin). Sound On Sound (January 2017) singled out the sequencer as the deal-clincher, but noted the missing power adaptor and the small number of memories. The monologue holds 100 programs: 80 presets and 20 user locations. Its System Exclusive dumps carry the program being edited, any single program with its sequence data, the global settings and the user scales and octaves. A Program Dump or an All Dump can be started from the panel over MIDI or USB, and a computer can request each type of data. Each program travels as 448 bytes packed into 512 MIDI bytes.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
42
Model ID
00 01 44
Default device ID
Global MIDI channel (GLOBAL 4, MIDI Ch 1-16), as 3g in the header

Receiving a dump

1. Press EDIT MODE until GLOBAL EDIT is shown. 2. Press button 6 (GLOBAL 4) and set MIDI Ch to the channel the dump was made with. 3. If the dump comes through the MIDI IN socket, set MIDI Route to USB+MIDI. 4. Send the file: a single program dump (function 4C) is written into the internal memory, a current program dump (40) goes into the edit buffer and must be saved with WRITE. The unit answers 23 (completed) or 24 (error).

Sending a dump from the instrument

Current program: press EDIT MODE until PROGRAM EDIT, press button 12 (DUMP), turn PROGRAM/VALUE until Press WRITE appears, press WRITE. It is sent from MIDI OUT and USB. All data: press EDIT MODE until GLOBAL EDIT, press button 15 (ALL DUMP), choose All Dump (USB) or All Dump (MIDI), turn PROGRAM/VALUE until Press WRITE appears, press WRITE. It takes about 10 seconds over USB and about 30 seconds over MIDI.

Requesting a dump

Current program: F0 42 3g 00 01 44 10 F7 (answer: function 40). One program: F0 42 3g 00 01 44 1C pp 00 F7, where pp is the program number (answer: 4C). Global data: F0 42 3g 00 01 44 0E F7 (answer: 51). User scale or user octave: functions 14 or 15 followed by the scale number (answers 44 or 45). g is the global MIDI channel minus 1. The unit answers 24 (Data Load Error) when it cannot comply.

SysEx pitfalls

Program data is 448 bytes packed 7-to-8 into 512 MIDI bytes and includes the step sequence; global data is 96 bytes packed into 110. A malformed message gets function 26 (Data Format Error). Some MIDI interfaces cannot pass the monologue's SysEx; Korg suggests USB.

Source: Korg monologue MIDI Implementation rev 1.00 (2019); monologue Owner's Manual pp. 35, 42, 46, 52 and MIDI chart ↗

Specifications

Synthesis
Analogue subtractive: 2 VCO, VCF with drive, EG, VCA, LFO
Polyphony
Monophonic
Oscillators
VCO 1 (saw, triangle, square) and VCO 2 (saw, triangle, noise), shape control, sync and ring modulation
Filter
Two-pole filter with cutoff and resonance, followed by a drive circuit
Memory
100 programs (80 presets, 20 user), each with sequence and microtuning settings
Keyboard / format
25 slim keys, velocity sensitive
Outputs
1 output jack, headphones; audio input; sync in and sync out
MIDI
MIDI In, MIDI Out, USB B (MIDI)

Known issues and maintenance

Auto Power Off switches the unit off after about four hours without use; it is enabled at the factory and can be disabled in GLOBAL EDIT. Korg warns that some MIDI interfaces cannot pass the monologue's SysEx messages and suggests using USB. The power adaptor is optional.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Korg monologue MIDI Implementation, revision 1.00 (2019.02.19) ↗ — SysEx header, device inquiry, dump and request formats, data sizes, program table with sequence data
  2. Korg monologue Owner's Manual (English, published 10/2024) ↗ — Key features, Program Dump and All Dump procedures, MIDI settings, factory reset, specifications, MIDI implementation chart
  3. Korg USA: monologue product page ↗ — Two-pole filter, 80 presets plus 20 user programs, five colours
  4. Korg USA: monologue downloads ↗ — List of manuals, MIDI implementation, Sound Librarian, system updater
  5. Paul Nagle, "Korg Monologue", Sound On Sound, January 2017 ↗ — Review: price, sequencer, filter and drive, criticisms
  6. Korg unveil Monologue monosynth, Sound On Sound news, 2 November 2016 ↗ — Announcement, planned January 2017 release, price, colours, Aphex Twin presets

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.