Korg prologue

Photo: Kazuhisa OTSUBO from Tokyo, Japan · CC BY 2.0 ↗

Korg · Synthesizer · 2018

Korg prologue

The Korg prologue is a polyphonic analogue synthesizer made in two versions: the prologue-16 with 61 keys and 16 voices, and the prologue-8 with 49 keys and 8 voices. Each voice has two VCOs with square, triangle and sawtooth waves plus a digital MULTI ENGINE that works as a noise generator, a VPM oscillator or a user oscillator, followed by a two-pole low-pass filter, two envelopes, an LFO and a VCA. Programs can layer, split or crossfade two timbres, and digital modulation, delay and reverb effects are built in; the prologue-16 adds an analogue low-frequency compressor. An SDK lets developers write their own oscillators and effects for 16 user slots each. Sound On Sound (April 2018) described it as a hybrid rather than a purely analogue synth and praised its sound, effects and arpeggiator, while criticising the single LFO, the non-standard MIDI CC map and the lack of aftertouch. The prologue has 500 program locations, 250 filled with factory presets. Its System Exclusive dumps carry the program being edited, any single program, the live set, the global settings, the user scales and octaves, and the contents of the user oscillator and effect slots. A Program Dump or an All Dump of programs, live set and global data can be started from the panel over MIDI or USB, and each type can be requested by a computer.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
42
Model ID
00 01 4B
Default device ID
Global MIDI channel (GLOBAL 5, MIDI Global Ch 1-16), as 3g in the header

Receiving a dump

1. Press EDIT MODE until GLOBAL EDIT is shown. 2. Press button 5 (GLOBAL 5) and set MIDI Global Ch to the channel the dump was made with. 3. If the dump comes through the MIDI IN socket, set MIDI Route to USB+MIDI. 4. Send the file: single program (4C), live set (46) and global (51) dumps are written into the internal memory; a current program dump (40) goes into the edit buffer and must be saved with WRITE. The unit answers 23 (completed) or 24 (error).

Sending a dump from the instrument

Current program: press EDIT MODE until FUNCTION mode, press button 7 (DUMP), turn PROGRAM/VALUE until Press WRITE appears, press WRITE. It is sent from MIDI OUT and USB. All data: in FUNCTION mode press button 8 (ALL DUMP), choose All Dump (USB) or All Dump (MIDI), turn PROGRAM/VALUE until Press WRITE appears, press WRITE. Programs, live set and global data are sent; about 10 seconds over USB and about 30 seconds over MIDI.

Requesting a dump

Current program: F0 42 3g 00 01 4B 10 F7 (answer: function 40). One program: F0 42 3g 00 01 4B 1C pp PP F7, where pp is the low 7 bits and PP the 8th bit of the program number (answer: 4C). Live set: F0 42 3g 00 01 4B 16 F7 (answer: 46). Global data: F0 42 3g 00 01 4B 0E F7 (answer: 51). g is the global MIDI channel minus 1. The unit answers 24 (Data Load Error) when it cannot comply.

SysEx pitfalls

Program data is 336 bytes packed 7-to-8 into 384 MIDI bytes; the live set is 128 bytes in 146; global data is 32 bytes in 37. User oscillator and effect slots use separate messages (functions 17-1E and 47-4A). In the MIDI Implementation the user scale and octave messages show the header 00 01 44 instead of 00 01 4B. Some MIDI interfaces cannot pass the prologue's SysEx; Korg suggests USB.

Source: Korg prologue MIDI Implementation rev 1.01 (2020); prologue Owner's Manual pp. 54, 59, 71 and MIDI chart ↗

Specifications

Synthesis
Analogue subtractive with digital MULTI ENGINE (noise, VPM, user oscillator)
Polyphony
16 voices (prologue-16), 8 voices (prologue-8)
Multitimbrality
2 timbres (main and sub) in layer, split or crossfade
Oscillators
2 VCO per voice (square, triangle, sawtooth) plus MULTI ENGINE (noise generator, VPM oscillator, user oscillator)
Filter
Two-pole low-pass VCF with resonance, drive and a low cut (high-pass) switch
Memory
500 programs (250 factory presets, 250 user at the factory); 16 user oscillator and 16 user effect slots
Keyboard / format
prologue-16: 61 keys; prologue-8: 49 keys; natural touch, velocity sensitive, no aftertouch
Outputs
Output L/MONO and R, headphones; sync in and sync out
MIDI
MIDI In, MIDI Out, USB B (MIDI)

Known issues and maintenance

Auto Power Off switches the unit off after four hours without use; it is enabled at the factory and can be disabled. Korg warns that some MIDI interfaces cannot pass the prologue's SysEx messages and suggests using USB.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Korg prologue MIDI Implementation, revision 1.01 (2020.2.10) ↗ — SysEx header, device inquiry, dump and request formats, data sizes, user slot messages
  2. Korg prologue Owner's Manual (English, published 02/2025) ↗ — Key features, Program Dump and All Dump procedures, MIDI settings, user oscillator, specifications, MIDI implementation chart
  3. Korg USA: prologue product page ↗ — Two models, two-pole low-pass filter, 500 programs, SDK with 16 user oscillator and 16 user effect slots
  4. Korg USA: prologue downloads ↗ — List of manuals, MIDI implementation, Sound Librarian, system updater
  5. Gordon Reid, "Korg Prologue", Sound On Sound, April 2018 ↗ — Review: prices, hybrid architecture, effects, arpeggiator, criticisms

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.