no image yet
Korg · Synthesizer

Korg Triton Extreme

The Korg Triton Extreme is a music workstation and sampler made with 61, 76 or 88 keys, the largest using the weighted RH2 action. Sound On Sound described it as the essence of the Triton Studio offered for less money. Its HI synthesis engine is the same as on earlier Tritons, but the PCM ROM grows to 160 MB with 962 multisamples and 1,175 drum samples. It plays up to 120 voices, holds 1,536 user Programs and 1,536 Combinations, and samples at 48 kHz into up to 96 MB of RAM. Its best-known addition is Valve Force, a stage built around a 12AU7 vacuum tube visible behind a window on the front panel. Storage moved to a Compact Flash slot and two USB ports. Sound On Sound concluded that the Extreme offers the best of everything the Triton had become. From Global mode the Triton Extreme sends System Exclusive dumps of Programs, Combinations, drum kits, arpeggio patterns, global settings and sequencer data, singly, by bank or all at once; a full dump is up to about 4 MB. Korg documents data compatibility with the Triton, Triton pro, proX and Triton-Rack through dumps and files, with some limits. Samples are not dumped and must be saved to media.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
42
Model ID
50
Default device ID
Global MIDI channel (3n in the header)

Receiving a dump

1. Set the sending device to the Triton Extreme global MIDI channel (Global 1-1a); data sent earlier needs the same global channel it was sent on. 2. In Global P1: MIDI check Enable Exclusive (1-1b), or open one of the Dump page menu commands: while it is shown, dumps are received regardless. 3. Turn off Memory Protect (Global 0-2b) for the data type. 4. Close other dialogs (except Media Save Exclusive) and leave cue list editing.

Sending a dump from the instrument

1. Connect MIDI OUT (or USB B) to the receiver. 2. Go to Global P1: MIDI. 3. From the page menu choose Dump Program, Dump Combination, Dump Drum Kit, Dump Arpeggio Pattern, Dump Global Setting, Dump Sequencer or Dump All. 4. Choose All, Bank or Single as offered and set To to MIDI OUT or USB. 5. Press OK. The display shows Now Transmitting MIDI Data.

Requesting a dump

Dump Request messages are supported when Enable Exclusive is checked, according to the Parameter Guide; the request format is in the separate MIDI Implementation document. With Enable Exclusive checked, selecting a Program or Combination also transmits its edit buffer.

SysEx pitfalls

Sizes: Program single 627 bytes (700 for EXB-MOSS bank), Combination single 521, Global 1,009, drum kit single 4,709, All dump 2,608,712 to 3,979,708 bytes, about 835 to 1,274 seconds over MIDI. After reception the unit needs up to about 3 seconds to write memory; leave that gap between dumps and do not store several dumps as one block in a data filer. Some USB-MIDI interfaces cannot pass its SysEx. Samples are not included.

Source: Korg TRITON Extreme Parameter Guide E2, Global P1 Dump pp. 162-164, Memory Protect p. 159, System exclusive p. 295, Data compatibility pp. 309-313 ↗

Specifications

Synthesis
HI (Hyper Integrated) synthesis, sample-based, with sampling
Polyphony
60 voices, max 120 in single mode; 30, max 60 in double mode
Multitimbrality
16 timbres / 16 tracks
Oscillators
1 or 2 oscillators per program; 160 MB PCM ROM, 962 multisamples, 1,175 drum samples
Filter
24 dB/oct resonant low pass, or 12 dB/oct low pass + high pass
Memory
1,536 user Programs (+128 with EXB-MOSS), 1,536 user Combinations, 144 user drum kits
Keyboard / format
61 keys, 76 keys, or 88 keys RH2 weighted
Outputs
Main L/MONO and R, 4 individual outputs, headphones, optical S/P DIF
MIDI
MIDI IN, OUT, THRU; USB B (MIDI to computer) and USB A

Known issues and maintenance

Calendar backup battery: when low the display warns Battery voltage for calendar IC; it is user-replaceable. Songs and samples are lost at power-off unless saved to media. If power is lost while received data is written, holding MENU and 9 at power-on recovers the unit but initialises memory.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Korg TRITON Extreme Parameter Guide (E2) ↗ — Dump commands, procedures, sizes and times, Enable Exclusive, Memory Protect, SysEx header 42 3n 50, data compatibility with TRITON, TRITON STUDIO and TRITON-Rack
  2. Korg TRITON Extreme Operation Guide (E2) ↗ — Specifications p. 138: polyphony, ROM, filters, memory, keyboards, outputs, MIDI, USB; calendar battery
  3. Korg USA support downloads: TRITON Extreme ↗ — Manuals, system updater, MOSS data
  4. Derek Johnson, "Korg Triton Extreme", Sound On Sound, May 2004 ↗ — Review: relation to Triton Studio, Valve Force, storage, criticisms, verdict

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.