Lexicon LXP-15
The Lexicon LXP-15 is a one-unit rack multi-effects processor. It works with 16-bit linear conversion at a 31.25 kHz sample rate and offers five fixed algorithms: Delay/Reverb, Pitch/Delay, Gate, Plate and Chorus Delay. It holds 128 factory presets and 128 user registers, and has two unbalanced inputs and outputs, five pedal and footswitch inputs, and MIDI In, Out and Thru. Any preset can be reshaped through patches that link MIDI controllers, notes, velocity, pedals, an internal LFO or an envelope follower to effect parameters. Sound On Sound reviewed it in January 1992, praising its reverbs and echoes and the quick access given by its paged front panel. The owner's manual documents the System Exclusive format in full. From the MIDI page the unit sends one register or all 128 registers; a single program dump is 74 bytes and the dump of all user data is 8,583 bytes. An active setup dump carries the current setup together with the system settings. A single program received over MIDI is stored in Register 1 unless another register has been chosen.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 06
- Model ID
- 06
- Default device ID
- MIDI channel (Sys page, MIDIchn 1-16 or OMNI), sent as the low nibble of byte 4
Receiving a dump
1. Turn PAGE to Sys and set MIDIchn to the channel used by the sender. 2. On the same page set MemProt to Off, otherwise registers cannot be overwritten. The manual shows no separate SysEx on/off setting.
Sending a dump from the instrument
1. Turn PAGE to MIDI. 2. Press the button under Registr. 3. Turn ADJUST to choose a register (1-128) or All. 4. Press the button under Send.
Requesting a dump
The manual says an active setup dump is sent in answer to a Data Request and mentions an Event Request to choose the target register, but the request bytes were not on the pages read.
SysEx pitfalls
Header F0 06 06, then the message type in the high nibble and the MIDI channel in the low nibble. Single program dump 74 bytes, all user data 8,583 bytes, active setup 129 bytes. A received single program goes to Register 1 unless an Event Request names another register. The manual prints the all-data byte count as 0x4280 in 7-bit, while the bytes shown are 43 00.
Source: Lexicon LXP-15 Owner's Manual 070-07831 Rev 1, pp. 2-8, 6-1, 6-4, 7-2 to 7-4
Specifications
- Synthesis
- Digital multi-effects, 16-bit linear PCM, 31.25 kHz sampling, 5 algorithms
- Memory
- 128 presets and 128 user registers
- Keyboard / format
- 1U rack unit, 483 x 45 x 353 mm
- Outputs
- 2 unbalanced 1/4 inch outputs (600 ohm, +4 dBu nominal); 2 unbalanced inputs
- MIDI
- MIDI In, Out, Thru
Known issues and maintenance
A factory reset (Clear ALL RAM in the power-on diagnostics, entered by holding VIEW) erases all user registers. In a brown-out the unit freezes and resets when power returns.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Lexicon LXP-15 Owner's Manual, part 070-07831 Rev 1 (ManualsLib copy) — System page, MIDI page and register send (pp. 2-8, 6-1, 6-4), SysEx formats and dump contents (pp. 7-2 to 7-4), troubleshooting and reset (pp. 8-1, 8-2), specifications
- Lexicon LXP-15 Quick Reference Guide, part 070-08457 Rev 1 ↗ — 128 presets, register store and recall, memory protect, copyright 1990
- Harman Help Center: LXP-15 and 15 II Factory Reset ↗ — Factory reset procedure that erases user registers
- Martin Russ and Gary Smith, Lex Is More, Sound On Sound, January 1992 ↗ — Review: five algorithms, 128 presets, patching, 16-bit 31.25 kHz conversion, UK price, verdict