no image yet
Lexicon · Effect Processor · 1994

Lexicon PCM 80

The Lexicon PCM 80 is a one-unit rack digital effects processor reviewed by Sound On Sound in December 1994 as the successor to the PCM 70. It has ten stereo algorithms in two classes, 4-voice and 6-voice, covering reverbs, multi-band delays, chorus, pitch glide and resonator effects, and 200 factory programs in four banks of 50. Its own memory holds one bank of 50 user registers, and a front PCMCIA slot takes RAM cards for more registers or algorithm cards such as Dual FX and Pitch FX. Conversion is 18-bit at 44.1 or 48 kHz, with balanced analogue and S/PDIF digital inputs and outputs. Reviewers praised its sound and its simple operation, and noted the patching system that links MIDI controllers, pedals and internal sources to most parameters. The Control menu dumps the current program, the internal register bank, card banks, program change maps, chains and setups as System Exclusive, and the MIDI documentation adds requests for almost every kind of data. A bank dump of 50 effects is about 70 KB. Effects made with a card algorithm can only be dumped while that card is loaded.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
06
Model ID
07
Default device ID
Device ID 0 (set at Control 3.7 after SysEx Receive On)

Receiving a dump

1. Press Control and go to matrix position 3.7, MIDI SysEx. 2. Set it to Receive On. 3. Set the Device ID (default 0) to match the Target ID of the sender.

Sending a dump from the instrument

1. Press Control and go to matrix position 3.8, MIDI Dump. 2. Turn ADJUST to choose the data: CurrentPgm, Bank R (internal registers), a card bank, a program change map, a chain, all internal or card chains, or a setup. 3. Press Store to transmit.

Requesting a dump

The MIDI Implementation Details document defines a Data Request message (identifier 7F) that asks for system configuration, a bank, a single effect, tables, chains and other data. A Single Effect request with bank 7F returns the running effect with unsaved edits.

SysEx pitfalls

Header F0 06 07 then the device ID and the message identifier. SysEx is ignored unless Control 3.7 is set to Receive On. Send no more than 3 SysEx messages every 20 ms. A bank dump is about 70,657 bytes and a single effect 1,421 bytes. Registers made with a card algorithm need the card loaded on both units; otherwise a placeholder is sent and the receiver leaves the effect unchanged. Banks that mix several cards need one dump per card.

Source: Lexicon PCM 80 User Guide 070-11263 Rev 1, pp. 5-3, 5-7, 5-8; PCM 80 V1.10 MIDI Implementation Details 070-11486

Specifications

Synthesis
Digital reverb and effects, 10 stereo algorithms (4-voice and 6-voice), 18-bit conversion, 44.1/48 kHz
Memory
200 factory programs (4 banks of 50), 50 internal user registers, more register banks on PCMCIA SRAM cards up to 1 MB
Keyboard / format
1U rack unit, 483 x 45 x 305 mm
Outputs
2 balanced outputs (XLR and 1/4 inch TRS), 2 balanced inputs (combined XLR and TRS), S/PDIF coaxial in and out
MIDI
MIDI In, Thru, Out

Known issues and maintenance

The service manual says to replace the internal battery at 2.75 V or lower. A factory reset (hold DOWN and TAP at power-on, then STORE) clears all user presets and settings. Sound On Sound noted about one second of muting while a program loads.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Lexicon PCM 80 User Guide, part 070-11263 Rev 1 (ManualsLib copy) — Introduction, program and register banks, MIDI operation, Control 3.4 and 3.7, Bulk Data Dumps, implementation chart, specifications
  2. Lexicon PCM 80 Version 1.10 MIDI Implementation Details, part 070-11486 (ManualsLib copy) — SysEx header, identifiers, enabling, timing, Bank Dump and Single Effect Dump sizes, Data Request, device inquiry response
  3. Lexicon PCM 80 Pitch FX Algorithm Card V1.1 User Guide, part 070-11674 Rev 1 ↗ — SysEx register dumps need the algorithm card loaded; placeholder behaviour and messages
  4. Lexicon PCM 80 Service Manual, part 070-10348 (Internet Archive) — Battery replacement threshold, MIDI connectors, sample rates, copyright 1995
  5. Paul White, Lexicon PCM80, Sound On Sound, December 1994 ↗ — Review: successor to PCM 70, presets, algorithms, SysEx dumps and automation, verdict
  6. Bob Dormon, Dream machine: Lexicon PCM 80, The Mix, February 1995 ↗ — Review: comparison with PCM 70, MIDI data dumps, UK price
  7. Harman Help Center: PCM 80, 81, 90 and 91 Factory Reset ↗ — Factory reset procedure

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.