no image yet
Oberheim · Synthesizer · 1988

Oberheim Matrix-1000

The Oberheim Matrix-1000 is a one-unit rack synthesizer module introduced in 1988. It has six analog voices, each with two digitally controlled oscillators, a four-pole low-pass filter and an amplifier, and it shares its sound architecture with the Matrix-6 keyboard. It plays one sound at a time through a single mono output, and several units can be chained in group mode to add voices. Its name comes from its memory: 1,000 patches, 800 of them fixed in ROM and 200 in RAM. The front panel has only a keypad, a three-character display and a volume knob, so sounds cannot be edited on the unit itself: reviewers pointed out that an editor program or a Matrix-6 is needed. Music Technology's Simon Trask wrote that the sounds themselves are "the real wealth of this instrument". System Exclusive is therefore the only way to change what the Matrix-1000 holds. The Data Dump function sends the current patch, the 100 patches of the current bank or the 200 RAM patches, each patch as its own message. The same messages are used by the Matrix-6 and Matrix-6R, and the manual describes exchanging patches with them. The unit also answers dump requests and accepts single parameter changes over SysEx.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

From compatible models

Oberheim Matrix-6 / Matrix-1000

Related models: Matrix-6

The Matrix-1000 owner's manual describes patch exchange with the Matrix-6 and Matrix-6R: same SysEx header and device ID.

SysEx guide

Manufacturer ID
10
Model ID
06 (shared with Matrix-6 and Matrix-6R)
Default device ID
None in patch dumps (no channel byte); basic channel 1 and Omni on after re-initialisation
Suggested delay between messages
10 ms

Receiving a dump

1. Connect the sender's MIDI Out to the Matrix-1000 MIDI In. 2. Press Select until Ext. Funct. lights, press 6: if the display reads Pon, press - (or Enter) so that it reads PoF. Memory Protect is now off. 3. Send the data. No special mode is needed: the patches are stored automatically. A single patch is stored at its patch number (0-99) in the currently selected bank; the RAM patches 000-199 are banks 0 and 1.

Sending a dump from the instrument

1. Connect the Matrix-1000 MIDI Out to the receiver's MIDI In. 2. Press Select until Data Dump lights. 3. Choose what to send with + and - or the number keys: 0 (display 0db) sends the 100 patches of the current bank, 1 (1do) sends the current patch, 2 (2dA) sends all RAM patches, 000 to 199. 4. Press Enter.

Requesting a dump

Send F0 10 06 04 type number F7. Type 0 requests all patches of the current bank and the master parameters, type 1 a single patch (number = patch 0-99), type 3 the master parameters, type 4 the edit buffer; number is 0 for types 0 and 3. A request for all returns 100 single patch messages followed by 50 dummy split patches (opcode 02), kept for compatibility with the Matrix-6.

SysEx pitfalls

Each patch is a separate message: F0 10 06 01, patch number, 134 data bytes sent as 268 nibbles (low nibble first), checksum, F7, 275 bytes in all. Leave at least 10 ms between patches sent to the unit. With Memory Protect on, incoming dumps are ignored; transmission is not affected. After a Dump all into another Matrix-1000 the receiver is left with bank lock on and bank 1 selected. A Matrix-6 or 6R with software 2.13 or earlier may send a SEND ALL faster than the Matrix-1000 can store it: resend the missing patches one at a time. Split and master data sent by a Matrix-6 are ignored.

Source: Oberheim Matrix-1000 Owner's Manual, Second Edition, July 1988 (part no. 950071), printed pp. 32-35, 38 and 42-45

Specifications

Synthesis
Analog subtractive synthesis with digitally controlled oscillators
Polyphony
6 voices; up to six units can be chained in group mode for 36 voices
Multitimbrality
None: one patch at a time
Oscillators
2 DCOs per voice, with sync
Filter
4-pole low-pass filter with its own envelope
Memory
1,000 patches: 000-199 in RAM (can be overwritten via MIDI), 200-999 in ROM
Keyboard / format
1U rack module
Outputs
1 mono audio output; no headphone socket
MIDI
In, Out, Thru

Known issues and maintenance

No sound editing from the front panel: an editor or a Matrix-6/6R is required. Re-initialisation: holding Enter while switching on resets the operating settings (MIDI channel 1, Omni on, Memory Protect off) without erasing the patches. Afterwards patch 000 is displayed but notes play a test tone instead of the patch sound. Calibration: Extended Function 7, test 0, then Enter retunes oscillators, filters and amplifiers (display CAL). Reviewers in 1988 noted slow patch selection with the three-digit display, zipper noise on pitch bend with some sounds and that the unit runs warm in a rack.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Oberheim Matrix-1000 Owner's Manual, Second Edition, July 1988 (part no. 950071) — Specifications, patch memory, group mode, Data Dump, Memory Protect, re-initialisation and the System Exclusive format. Copy hosted by ManualsLib, not by Oberheim.
  2. Martin Russ, "Oberheim Matrix 1000", Sound On Sound, September 1988 ↗ — Voice hardware with two DCOs per voice, RAM and ROM patches, transfers with the Matrix-6, connections, criticisms
  3. Simon Trask, "Oberheim Matrix 1000", Music Technology, August 1988 ↗ — Launch review: UK price, no editing on the unit, loading sounds by SysEx from a Matrix-6 or an editor, verdict on the sounds
  4. Paul White, "Oberheim Matrix 1000", Sound On Sound, June 1994 ↗ — Launch in 1988, oscillators and 4-pole filter, not multitimbral, relaunch in a cream finish