Rocktron Intellifex
The Rocktron Intellifex is a rack-mount digital multi-effects processor aimed at guitarists. It combines Rocktron's HUSH noise reduction, implemented digitally at the input, with reverb, delay, chorus, pitch shifting and ducking effects arranged in fixed configurations, together with a mixer section for the dry and effect levels. Rocktron built several versions of the design: the original Intellifex, the Intellifex LTD, the Intellifex XL and the Intellifex On-Line. The manual Rocktron publishes under the Intellifex name is that of the LTD, a 24-bit processor with 80 user and 80 factory presets, up to eight MIDI controller assignments per preset, program mapping and a 16-character display. Rocktron says the original Intellifex came with the Utopia factory presets. User presets can be sent as System Exclusive messages, one at a time to another unit or all together to a sequencer. A single preset carries the parameter values, title and controller assignments; a full user dump also includes the program map, MIDI channel, footswitch types and power-on preset and takes about three minutes. Rocktron's preset library states that its Intellifex On-Line presets load into the Intellifex and Intellifex LTD as bulk loads.
SysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 00 00 29
- Default device ID
- MIDI channel 1-16, Omni or Off (MIDI Channel function); the factory default is not stated
Receiving a dump
1. Connect the sender's MIDI Out to the Intellifex MIDI In. 2. Turn FUNCTION SELECT fully clockwise to MIDI DUMP/LOAD (in a user preset). 3. Turn PARAMETER SELECT to LOAD USER DATA for a full dump, or to Preset Load and choose the destination preset for a single preset. 4. Play back the data no faster than it was recorded and do not touch the controls until USER DATA LOADED appears.
Sending a dump from the instrument
1. Connect the Intellifex MIDI Out to the sequencer MIDI In. 2. Turn FUNCTION SELECT fully clockwise to MIDI DUMP/LOAD. 3. Turn PARAMETER SELECT to DUMP USER DATA (or Preset Dump to send only the selected user preset). 4. Start the sequencer recording. 5. Press STORE. The display counts the 82 data strings and shows USER DATA DUMPED after about 3 minutes.
Requesting a dump
No dump request message is documented; dumps are started from the front panel.
SysEx pitfalls
Steps and format are from the Intellifex LTD manual: header F0 00 00 29 02, command 28H preset dump, 2AH/2BH user dump, 200 data bytes per preset (values split into two 7-bit bytes), XOR checksum. RECEIVE ERROR appears if strings arrive too fast or a control is touched; DUMP ERROR if MIDI arrives while dumping.
Specifications
- Synthesis
- Digital effects: HUSH noise reduction, reverb, delay, chorus, pitch shift, ducker
- Memory
- Intellifex LTD: user presets 1-80, factory presets 81-160
- Keyboard / format
- Rack unit
- Outputs
- Intellifex LTD: left and right 1/4 inch outputs
- MIDI
- Intellifex LTD: MIDI In (7-pin, phantom power for MIDI Mate), MIDI Out/Thru
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Rocktron Intellifex(tm) Manual (Intellifex LTD user's manual, 1995), rocktron.com, Wayback copy 2024-09-15 ↗ — Features, presets, rear panel, MIDI dump/load procedures and byte format, MIDI chart, specifications; live page returned HTTP 500
- Rocktron Patchbay: Intellifex, rocktron.com, Wayback copies 2010 and 2024 ↗ — Preset files as bulk loads; On-Line presets compatible with Intellifex and Intellifex LTD; Utopia presets of the original Intellifex
- Intellifex On-Line Manuel d'utilisation (French), rocktron.com, Wayback copy 2004-12-05 ↗ — Same MIDI Dump/Load procedure and SysEx row for the On-Line model
Sign in to write a comment.
Comments
0