The Roland MKS-80 Super Jupiter is an eight-voice analog synthesizer in a 2U rack case, released in 1984 as part of Roland's Jupiter line. Each voice has two voltage-controlled oscillators with sawtooth, triangle, square and pulse waves, oscillator sync and cross modulation, a high-pass filter, a resonant low-pass filter and two envelopes. It responds to velocity and aftertouch received over MIDI. Sounds are organised in two layers: 64 tone memories hold the synthesis settings, and 64 patch presets combine tones in whole, split or dual key modes together with performance settings. An M-64C cartridge adds 128 of each. Parameters are selected digitally and shown on a 16-character display, so the optional MPG-80 programmer, with a control for each parameter, is the usual companion. Electronics & Music Maker called the module "undoubtedly the star" of Roland's MIDI range in 1984, and in 1990 Music Technology still preferred it to other classic analog polysynths for its warmth and clarity. According to the owner's manual, the contents of memory can be saved to and loaded from another MKS-80 or a computer over MIDI, using exclusive messages with the MIDI Function switch in position III. Roland still offers the factory patches as MIDI files.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 41
Receiving a dump
1. Set the Save/Load switch to MIDI. 2. Set the MIDI Function switch to III. 3. Set the Protect switch of the MKS-80 to OFF. 4. Start the load with the Load button and Write/Execute: the display shows LOAD all banks, then LOADING, then LOAD COMPLETE. 5. Set the Protect switch back to ON and the MIDI Function switch back to I or II.
Sending a dump from the instrument
1. Set the Save/Load switch to MIDI. 2. Set the MIDI Function switch to III. 3. On the receiving unit set the Protect switch to OFF. 4. Press Save. To send only some banks, hold Save and press the Bank buttons. 5. While holding Save, press Write/Execute: the display shows SAVING, then SAVE COMPLETE after about a second. 6. Set the receiver's Protect switch back to ON and the MIDI Function switch back to I or II.
SysEx pitfalls
The display shows REJECTED when the other device cannot send or receive, and MEMORY PROTECTED when the Protect switch is ON. If a save or load does not finish, press Write/Execute to return to the previous state and try again. Exclusive messages work only with the MIDI Function switch on III.
Specifications
- Synthesis
- Analog subtractive with voltage-controlled oscillators (VCO)
- Polyphony
- 8 voices
- Multitimbrality
- Two tones at once in Split or Dual key mode (Whole, Split, Dual)
- Oscillators
- Two VCOs per voice (16 in all): sawtooth, triangle, square and pulse; noise on VCO-2; sync and cross modulation
- Filter
- High-pass filter followed by a resonant low-pass VCF (does not self-oscillate)
- Memory
- 64 tone memories and 64 patch presets; an M-64C cartridge adds 128 of each
- Keyboard / format
- 2U rack module
- MIDI
- MIDI In, Out and Thru; separate 6-pin connector for the MPG-80 programmer
Known issues and maintenance
Memory is kept by a backup battery. The manual tells the user to set the Protect switch to ON before switching the MKS-80 on, otherwise the data in memory may be lost, and to leave it ON except while writing.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Roland MKS-80 Owner's Manual ↗ — Specifications, key modes, Protect switch, battery backup, saving and loading over MIDI. The Roland scan has no text: headings read on ManualsLib (manual 1001029), text through an unofficial edited transcription
- Roland support: Factory Patches (D-series, JUNO-1/2, MKS-series, U-series, GP-8, GR-50) ↗ — Roland distributes .mid files for loading the original MKS-80 factory patches
- Adam Douglas, "JUPITER: King of the Polysynths", Roland Articles, 27 May 2022 ↗ — Release in 1984, after the Jupiter-6 of 1983
- Dan Goldstein, "Roland Mother Keyboard System", Electronics & Music Maker, October 1984 ↗ — Eight voices, two VCOs per voice, tone memories and patch presets, M-64C cartridge, 2U rack, display, MPG-80, price and verdict
- Steve Howell, "The Jupiter Legacy", Music Technology, February 1990 ↗ — Oscillator waveforms, sync and cross modulation, filters, envelopes, key modes, MPG-80, reputation