no image yet
Roland · Sampler · 1986

Roland S-50

The Roland S-50 is a 61-key sampling keyboard released in 1986. It is 16-voice polyphonic, records at 30 or 15 kHz into 512k words of wave memory split into two banks, and responds to velocity and aftertouch. Its memory holds 32 tones and 8 patches, and up to four patches can play at once on separate MIDI channels. Editing is done on the built-in display or on an external RGB or composite monitor, and an optional digitizer tablet lets the user draw waveforms and envelopes. Four individual outputs sit beside the mix output, and all data, including the operating system, are loaded from 3.5 inch disks. With the Exclusive switch on, the S-50 exchanges Roland System Exclusive messages. The address map covers patch, tone, function and MIDI parameters and the wave data of both banks, using data requests and the Roland handshake protocol.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
41

Receiving a dump

Set the Exclusive switch to on in MIDI mode (page 13 EXCLUSIVE) and set the device ID in MIDI mode (display 1-16 = codes 0-15).

Requesting a dump

Send RQ1 (11H) or, with handshake, RQD (41H) with a 3-byte address and 3-byte size. The S-50 answers RQ1 with DT1 and RQD with DAT, or with RJC if address or size are wrong. Base addresses: directory 00 00 00, patch parameters 00 08 00, function 00 48 00, MIDI 00 4C 00, tone parameters 00 50 00, wave data A 08 00 00, wave data B 28 00 00.

SysEx pitfalls

The S-50 never sends RQ1 or WSD itself, so a computer or another device must start the transfer. It also sends DT1 when a tone parameter is edited on the panel. The manual's model ID statement contradicts its own message tables.

Source: Roland S-50 Owner's Manual v2.0, p. 94 and MIDI implementation Ver. 2.00 (pp. 127-131) ↗

Specifications

Synthesis
Sampling, 30 or 15 kHz
Polyphony
16 voices
Multitimbrality
Multi Patch Play: up to 4 patches on 4 receive channels
Memory
32 tones and 8 patches in RAM (wave data 512k words); saved to 3.5 inch disk
Keyboard / format
61 keys, velocity and aftertouch
Outputs
Mix output, 4 individual outputs, headphones
MIDI
3 MIDI connectors

Known issues and maintenance

Volatile memory: switching off erases all data and the system must be booted from the system disk.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Roland S-50 Owner's Manual, Version 2.0 ↗ — Features p. 3, important notes p. 7, MIDI mode pp. 93-94, specifications p. 116, MIDI implementation pp. 127-131 (commands, device ID, address map)
  2. Paul Wiffen, "Roland S50", Music Technology, December 1986 ↗ — Review: price, 12-bit sampling at 30 or 15 kHz, disks, monitor, verdict