no image yet
Roland · Sampler · 1993

Roland S-760

The Roland S-760 is a 16-bit stereo digital sampler in a single rack unit, introduced in 1993. It plays 24 voices, samples at rates from 16 to 48 kHz and comes with 2 MB of wave RAM, expandable to 32 MB. Samples are organised in Roland's layered structure: samples go into Partials, with a resonant low-pass, band-pass or high-pass filter, envelopes and LFO, Partials are mapped across the keyboard in Patches, and Patches are combined in multitimbral Performances inside a Volume. It has a floppy drive and a SCSI port, four individual outputs plus the stereo pair, and an optional OP-760-1 board for a video monitor, mouse and digital I/O. It reads the sound libraries of the Roland S-770 and S-750 as well as Akai S1000 sounds, and Sound On Sound called it the best value 16-bit stereo sampler of its day. The S-760 uses System Exclusive in two ways. A Volume Dump sends the parameters of the Volume in memory, from Performances down to Partials, as Roland SysEx; the wave data is not included, and after the dump is reloaded the sampler fetches the samples from the drive they came from. A System Dump sends the global settings. Wave data itself travels by the MIDI Sample Dump Standard, without names, key ranges or envelopes.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
41
Model ID
34
Default device ID
Device ID 0-31 (00H-1FH), set in System > MIDI page 2; factory value not documented

Receiving a dump

1. Connect the drive or CD-ROM that holds the samples used by the Volume and set it as Current Drive (Disk > Load). 2. MODE > F6 System > 3 MIDI, page 2 (Volume Dump). 3. Set Device ID to the value used when the dump was recorded. 4. Set Exclusive RX to On. 5. Go to Performance Play and do not play the unit while data arrives.

Sending a dump from the instrument

1. Connect MIDI OUT/THRU to the sequencer's MIDI IN. 2. MODE > F6 System > 3 MIDI, page 1: set MIDI Out/Thru to Out. 3. Go to page 2 (Volume Dump) and set Device ID. 4. Set Interval (16 to 128 KB, or All) to what the sequencer can record at once. 5. Start recording and press F3 VolDump. If the dump is split, save each part and answer Continue Volume Dump Function with F1. 6. Press F2 SysDump instead to send the system data.

Requesting a dump

Data request RQ1 (11H) with a 4-byte address and 4-byte size is answered with DT1; handshake RQD (41H) is answered with DAT. Main addresses: 00 00 00 00 Volume, 00 01 00 00 Performances, 00 04 00 00 Patches, 00 08 00 00 Partials, 00 0C 00 00 Sample parameters.

SysEx pitfalls

Volume Dump carries parameters only; the samples must be on the same CD-ROM or drive, with unchanged names, when the dump is reloaded. One Volume is about 250 KB of SysEx. Reload split dumps in the original order and at the recorded tempo or slower. Samples received by Sample Dump cannot be restored by Volume Dump. Do not write the 256th Partial slot with Data set.

Source: Roland S-760 Owner's Manual, Advanced 3-97 to 3-100 and 6-8 to 6-13; S-760 MIDI Implementation (Nov. 18 1993) pp. 3-4 ↗

Specifications

Synthesis
16-bit sampling, DI (Differential Interpolation) playback, 16 to 48 kHz
Polyphony
24 voices
Multitimbrality
Performances with multiple Parts, each on its own MIDI channel
Oscillators
Up to 512 samples in memory; 2 MB wave RAM, up to 32 MB
Filter
Per Partial: low-pass, band-pass or high-pass, with cutoff and resonance
Memory
In RAM: 1 Volume, 64 Performances, 128 Patches, 255 Partials, 512 Samples; saved to floppy or SCSI
Keyboard / format
1U rack module
Outputs
Stereo out plus 4 individual outputs, headphones; digital I/O with the OP-760-1 option
MIDI
MIDI In, Out/Thru (one switchable connector)

Known issues and maintenance

Sound data in memory is lost when the power is turned off and must be saved to disk. Roland US still offers system software version 2.24 and the SDISK utility to make a system disk.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Roland S-760 MIDI Implementation, Version 1.00, Nov. 18 1993 (scanned PDF read as page images) ↗ — Model ID 34H, device ID 00H-1FH, one-way and handshake commands, parameter address map, Sample Dump Standard for wave data
  2. Roland S-760 Owner's Manual, Advanced and Basic Operation (scanned PDF read as page images) ↗ — MIDI Volume Dump and System Dump settings (Adv. 3-97 to 3-100), Volume Dump and Sample dump procedures (Adv. 6-8 to 6-13), MIDI Implementation Chart Sep. 30 1993 (Adv. 7-22), specifications (Adv. 7-23, 7-24)
  3. Roland US, S-760 Digital Sampler product page ↗ — Discontinued; RAM to 32 MB, OP-760-01 board, Akai S1000 library compatibility, system version 2.24 download
  4. Paul Wiffen, Roland S760, Sound On Sound, February 1994 ↗ — Review: 24 voices, 4 outputs, filter modes, S770 library compatibility, verdict
  5. Jim Norman, The Roland S-760 Demystified, Keyboard, January 1996 (Roland US reprint) ↗ — Architecture (Sample, Partial, Patch, Performance), TVF modes, Volume Dump use, SCSI sample dump

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.