Roland SRV-330
The Roland SRV-330 Dimensional Space Reverb is a one-unit rack digital reverb from 1993. It works at 44.1 kHz with 16-bit converters and offers 100 user and 300 preset programs. Its algorithms include dense reverbs adapted from Roland's R-880 studio reverb and three-dimensional effects built on RSS (Roland Sound Space), which place early reflections at positions around the listener. Stereo algorithms process left and right channels independently. Parameters can be controlled in real time from expression pedals or MIDI: notes, velocity, control changes, channel pressure and pitch bend can be assigned to program parameters. It was sold alongside the SDE-330 Dimensional Space Delay. The SRV-330 sends its system settings and any range of the 100 user programs as a Roland System Exclusive bulk dump, either to a sequencer for storage or directly to a second SRV-330. To load a dump back, Memory Protect must be off and the receive channel must match the one used when the dump was made.
SysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 41
- Model ID
- 59
- Default device ID
- Receive MIDI channel minus 1 (00H-0FH); channel 1 gives 00H
Receiving a dump
1. Press SYSTEM and set Memory Protect (function 9) to OFF. 2. Set the receive MIDI channel (function 2) to the channel used when the dump was made. 3. Send the data: the display shows Receiving.
Sending a dump from the instrument
1. Press SYSTEM. 2. Select 8:Bulk Dump with the ALPHA DIAL or the arrow buttons. 3. Press PAGE. 4. Set the START point (SYSTEM or program 1-100) with the ALPHA DIAL. 5. Set the END point with the arrow buttons; it must not be before START. 6. Press MEMORY: the display shows Now Dumping. 7. Press SYSTEM or EXIT to return to Play mode.
Requesting a dump
The MIDI Implementation documents RQ1 (11H) with 3-byte address and size and says the SRV-330 does not transmit it. Bulk addresses: 00 00 00 system parameters, 00 08 00 programs 1-100 (08 00H apart), ending with an End Of Bulk mark.
SysEx pitfalls
Addresses are 3 bytes, not 4. Even in Omni mode, SysEx is accepted only on the receive channel matching the device ID. If Memory Protect is ON the unit shows Memory is Protected! and ignores the data. A bulk dump must end with the End Of Bulk mark.
Specifications
- Synthesis
- Digital reverb, RSS 3-D and R-880 derived algorithms; 16-bit, 44.1 kHz
- Memory
- 100 user programs (1-100), 300 preset programs (101-400)
- Keyboard / format
- 1U rack module
- Outputs
- Output L (mono) and R, -20/+4 dBm switchable; inputs L (mono) and R
- MIDI
- MIDI In, Out, Thru
Known issues and maintenance
A lithium battery keeps the settings; the message Battery low! Please Change! asks for replacement by a Roland service centre. Memory Protect must be OFF to store programs and to receive bulk data. Factory reset: power on holding PROGRAM and SYSTEM, choose the data group, press MEMORY.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Roland SRV-330 Owner's Manual, 1993 (scanned PDF read as page images) ↗ — Features p. 3, Memory Protect p. 36, MIDI system functions pp. 39-40, Bulk Dump and Bulk Load pp. 43-45, error messages and battery p. 52, initialization p. 53, MIDI chart Mar. 30 1993 p. 54, specifications p. 55
- Roland SRV-330 MIDI Implementation, Version 1.00, Jun. 18 1993 (scanned PDF read as page images) ↗ — Model ID 59H, device ID rule, RQ1 and DT1 formats, address block map, program parameter table
- Dave Lockwood, One Step Beyond (Roland SDE330), Sound On Sound, October 1993 ↗ — Says the SDE330 delay is the companion of the SRV330 reverb, reviewed in SOS August 1993
Sign in to write a comment.
Comments
0