no image yet
Roland · Drum Machine · 1987

Roland TR-626

The Roland TR-626 Rhythm Composer is a drum machine from 1987 built on digitally recorded drum sounds. It has 30 drum voices in 8 voice groups, covering kit sounds and Latin percussion, with level and pitch adjustable for each voice and 8 multi outputs alongside the stereo output. It holds 48 preset and 48 user rhythm patterns and 6 tracks of up to 999 bars in total, programmed by step or tap writing with accent, flam and shuffle. An M-128D memory card triples the memory, and data can also be saved to cassette. Over MIDI the TR-626 can send its whole Bank 1 memory, meaning rhythm patterns, tracks and the level and pitch settings of each voice, as a block of Roland System Exclusive data to another TR-626 or to any device able to record exclusive messages.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
41
Model ID
1D
Default device ID
Device ID = MIDI basic channel (the reception channel)

Receiving a dump

1. Set the receiver's reception (basic) channel to the same channel as the transmitter, and select memory Bank 1 (internal memory) on both. 2. With the TR-626 stopped in Track Play mode, hold Shift and press SYNC/MIDI (Main Key 15), then press Enter 5 times: the display shows Exc t. 3. Press Up to change it to Exc r, then press Start/Stop: the display shows Exc r- and the TR-626 waits for data. The received data replaces Bank 1.

Sending a dump from the instrument

1. Connect MIDI OUT to the receiver's MIDI IN and select memory Bank 1. 2. With the TR-626 stopped in Track Play mode, hold Shift and press SYNC/MIDI (Main Key 15), then press Enter 5 times: the display shows Exc t. 3. Press Start/Stop: the display shows Exc t- and the data is sent. The transfer takes about 5 seconds.

SysEx pitfalls

Only Bank 1 can be transferred: to send the data of memory card banks 2 or 3, copy it to Bank 1 first. One-way transfer only, no request message. The receiver shows Err and stops on an error; Start/Stop on both units cancels a transfer. The device ID byte follows the basic channel, so the receiving channel must match the one used when the data was sent.

Source: Roland TR-626 Owner's Manual (1987), pp. 78, 91-93 and MIDI implementation pp. 112-113 ↗

Specifications

Synthesis
Digitally recorded (sampled) drum voices
Oscillators
30 drum voices in 8 voice groups; voices in the same group do not sound together
Memory
48 preset and 48 user patterns; 6 tracks (max. 999 bars total); x3 with M-128D memory card
Keyboard / format
Tabletop drum machine with 16 main keys
Outputs
Stereo Out L and R (R is mono out), headphones, 8 multi outs, trigger out (rim shot)
MIDI
MIDI In, Out

Known issues and maintenance

Memory is kept by the batteries: if they run out or are inserted wrongly, the data is lost after power-off, even when an AC adaptor is used, so batteries must stay in the battery box. Roland advises replacing all batteries once a year and saving data to tape or a memory card before removing them. After fitting batteries the unit must be initialized (hold Mode and Pattern Group A while switching on), which erases all data.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Roland TR-626 Owner's Manual (1987) ↗ — Scanned PDF read as page images. Memory backup p. 5, outline p. 7, MIDI function p. 78, exclusive transfer pp. 91-93, specifications pp. 105-106, MIDI implementation (DT1, model ID 1DH, Bank 1 address map) pp. 112-113