no image yet
Roland · Sound Module · 1988

Roland U-110

The Roland U-110 is a 1U rack PCM sound module released in 1988. It plays sampled instrument sounds from its DC-PCM sound source with up to 31 voices, split across six parts that each listen on their own MIDI channel. It contains 99 preset tones, and up to four optional sound library cards can be inserted at once to add more. Its 64 patches store the part settings together with the built-in chorus and tremolo, and six separate outputs plus a stereo mix let each part be processed on its own. The Bulk Dump function in Utility mode sends the setup data, the temporary patch or all 64 patches as Roland System Exclusive messages, to another U-110 or to a sequencer. The same blocks can be requested with RQ1 messages.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
41
Suggested delay between messages
20 ms

Receiving a dump

1. Set the receiving U-110 Control Channel to the same number used by the sender. 2. In Setup, set Exclusive to ON. 3. To receive patches 1-64, set Memory Protect to OFF. 4. Play back the dump into MIDI IN; the receiving unit needs no other operation.

Sending a dump from the instrument

1. Connect the U-110 MIDI OUT to the sequencer or other U-110. 2. Press EDIT. 3. Select UTIL with the cursor buttons and press ENTER. 4. Select BULK and press ENTER. 5. Choose the block with the cursor buttons: SETUP, TEMP PATCH or 1-64 PATCH. 6. Press ENTER. The display shows Transmitting..., then Dump Complete. 7. Press EXIT three times to return to Play mode.

Requesting a dump

Send RQ1 with one of these address and size pairs: setup 01 00 00 / 00 00 20; temporary patch 01 01 00 / 00 02 00; patches 1-64 02 00 00 / 01 00 00; program change maps 06 00 00 / 00 18 00. The U-110 answers with DT1. Requests are recognized only when Exclusive is ON.

SysEx pitfalls

Manual bulk dump is sent even with the exclusive switch off. The setup dump includes the program change maps. Patches 1-64 travel as 128 packets of 127 bytes. Receiving setup resets controllers; receiving the temporary patch also mutes sounds. The generic Roland section asks for at least 20 ms between messages in long one-way transfers.

Source: Roland U-110 Owner's Manual (1988), pp. 66-68, 84, 88-91 ↗

Specifications

Synthesis
PCM sample playback (DC-PCM)
Polyphony
31 voices
Multitimbrality
6 parts, each on its own MIDI channel
Memory
64 patches; 99 preset tones; 4 sound library card slots
Keyboard / format
1U rack module (482 x 358 x 45 mm)
Outputs
Multi outputs 1-6, Mix output L/R, headphones
MIDI
MIDI In, Out, Thru

Known issues and maintenance

Backup battery. A battery keeps the memory; Roland suggests replacing it about every five years. When it is low the display shows Check Battery! and the memory may be lost.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Roland U-110 Owner's Manual (1988) ↗ — Features p. 10, battery p. 7, bulk dump pp. 66-68, Roland exclusive format p. 84, MIDI implementation pp. 88-91, specifications p. 93