Roland U-110
The Roland U-110 is a 1U rack PCM sound module released in 1988. It plays sampled instrument sounds from its DC-PCM sound source with up to 31 voices, split across six parts that each listen on their own MIDI channel. It contains 99 preset tones, and up to four optional sound library cards can be inserted at once to add more. Its 64 patches store the part settings together with the built-in chorus and tremolo, and six separate outputs plus a stereo mix let each part be processed on its own. The Bulk Dump function in Utility mode sends the setup data, the temporary patch or all 64 patches as Roland System Exclusive messages, to another U-110 or to a sequencer. The same blocks can be requested with RQ1 messages.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 41
- Suggested delay between messages
- 20 ms
Receiving a dump
1. Set the receiving U-110 Control Channel to the same number used by the sender. 2. In Setup, set Exclusive to ON. 3. To receive patches 1-64, set Memory Protect to OFF. 4. Play back the dump into MIDI IN; the receiving unit needs no other operation.
Sending a dump from the instrument
1. Connect the U-110 MIDI OUT to the sequencer or other U-110. 2. Press EDIT. 3. Select UTIL with the cursor buttons and press ENTER. 4. Select BULK and press ENTER. 5. Choose the block with the cursor buttons: SETUP, TEMP PATCH or 1-64 PATCH. 6. Press ENTER. The display shows Transmitting..., then Dump Complete. 7. Press EXIT three times to return to Play mode.
Requesting a dump
Send RQ1 with one of these address and size pairs: setup 01 00 00 / 00 00 20; temporary patch 01 01 00 / 00 02 00; patches 1-64 02 00 00 / 01 00 00; program change maps 06 00 00 / 00 18 00. The U-110 answers with DT1. Requests are recognized only when Exclusive is ON.
SysEx pitfalls
Manual bulk dump is sent even with the exclusive switch off. The setup dump includes the program change maps. Patches 1-64 travel as 128 packets of 127 bytes. Receiving setup resets controllers; receiving the temporary patch also mutes sounds. The generic Roland section asks for at least 20 ms between messages in long one-way transfers.
Source: Roland U-110 Owner's Manual (1988), pp. 66-68, 84, 88-91 ↗
Specifications
- Synthesis
- PCM sample playback (DC-PCM)
- Polyphony
- 31 voices
- Multitimbrality
- 6 parts, each on its own MIDI channel
- Memory
- 64 patches; 99 preset tones; 4 sound library card slots
- Keyboard / format
- 1U rack module (482 x 358 x 45 mm)
- Outputs
- Multi outputs 1-6, Mix output L/R, headphones
- MIDI
- MIDI In, Out, Thru
Known issues and maintenance
Backup battery. A battery keeps the memory; Roland suggests replacing it about every five years. When it is low the display shows Check Battery! and the memory may be lost.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Roland U-110 Owner's Manual (1988) ↗ — Features p. 10, battery p. 7, bulk dump pp. 66-68, Roland exclusive format p. 84, MIDI implementation pp. 88-91, specifications p. 93