Roland VG-8
The Roland VG-8 V-Guitar System is a floor unit from 1995 that turns an ordinary steel-string guitar into a modelling instrument. A GK-2A divided pickup sends the signal of each string separately, and the VG-8 rebuilds the sound in DSP using Roland's COSM approach: Variable Guitar Modeling recreates guitar bodies, pickups and their positions, amplifiers, speakers and microphones, while Harmonic Restructure Modeling reshapes the string harmonics into new, synth-like sounds that still follow the player's touch. Because each string is processed on its own, the VG-8 can retune strings, simulate a 12-string or a bass, and spread strings across the stereo field. Modulation, delay, reverb and EQ are built in. Sound On Sound found it very impressive, especially for rock tones, hex distortion and 12-string sounds. Roland later named the VG-88 as its successor. The VG-8's patches and system settings can be saved as System Exclusive data. From the System MIDI page the unit sends all patches, the system settings or both to a sequencer, and it accepts the same data back at any time while switched on, overwriting its current settings. Both ends must use the same device ID, 17 by factory default.
SysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 41
- Default device ID
- Device ID 17 (factory); range 1-32
Receiving a dump
1. Connect the sequencer's MIDI OUT to the VG-8 MIDI IN. 2. Press SYSTEM, then F3 (MIDI). 3. Set Device ID to the number used when the data was sent. 4. Play the data: the VG-8 receives SysEx at any time while it is on, and overwrites the current settings.
Sending a dump from the instrument
1. Connect the VG-8 MIDI OUT to the sequencer's MIDI IN. 2. Press SYSTEM, then F3 (MIDI). 3. Check the Device ID and note it. 4. Set Bulk Dump to All Patches, System, or Patches & System. 5. Start recording on the sequencer. 6. Press F1 (BULK): the display shows Sending, then Completed. 7. Stop recording and save the data.
SysEx pitfalls
Data is received only when sender and receiver have the same device ID; if the device ID used is forgotten, the saved data cannot be loaded. A Patches & System dump replaces all current settings.
Source: Roland VG-8 Owner's Manual, pp. 53-55, 86 and MIDI Implementation Chart p. 104 ↗
Specifications
- Synthesis
- COSM modelling: Variable Guitar Modeling (VGM) and Harmonic Restructure Modeling (HRM)
- Keyboard / format
- Floor unit with foot pedals; GK-2A divided pickup input
- Outputs
- Mix Out L (mono) and R, Guitar Out, headphones; AUX In L (mono) and R
- MIDI
- MIDI In, Out
Known issues and maintenance
A backup battery keeps the memory; Roland gives it 5 years or more and recommends replacing it every 5 years; INT. Battery Low appears when it is weak. The GK-2A driver settings must match the installed pickup, otherwise noise or distortion can result.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Roland VG-8 V-Guitar System Owner's Manual (scanned PDF read as page images) ↗ — Memory backup p. 3, COSM, VGM and HRM p. 4, Bulk Transmission pp. 53-55, System MIDI and Bulk Dump p. 86, specification p. 103, MIDI chart Feb. 1 1995 p. 104
- Roland US, VG-8 product page ↗ — Discontinued; COSM modelling, GK-2A pickup, polyphonic pitch shifter, VG-88 as successor; lists 128 preset and 64 user patches
- Paul White, Roland VG8, Sound On Sound, May 1995 ↗ — Review: VGM and HRM, GK-2A, connections, 64 preset and 64 user patches plus card, patch dumps over MIDI, verdict
Sign in to write a comment.
Comments
0