Sequential Circuits OB-6
The OB-6 is a six-voice analog polyphonic synthesizer with a four-octave keyboard. It reached the shops in 2016 as the Dave Smith Instruments OB-6 and was designed by Dave Smith together with Tom Oberheim; its manual is now published by Sequential and the instrument is also presented on the Oberheim website. The aim, in Dave Smith's words in the manual, was to bring back the sound of Oberheim's SEM-based polyphonic synthesizers in a modern format. Each voice has two voltage-controlled oscillators, a sub-octave and white noise, followed by a two-pole state-variable filter that moves from low-pass through notch to high-pass and can be switched to band-pass. Two digital effects with true bypass, a polyphonic step sequencer of up to 64 steps and an arpeggiator complete it. Reviewing it for Sound On Sound in 2016, Gordon Reid wrote that it has a sound that "screams 1979 at you"; he listed the short keyboard and the lack of splits and layers among its limits. Memory holds 1000 programs: 500 factory programs that cannot be erased and 500 user programs. The Pgm Dump command sends the current program, ten programs, a bank, all user banks or everything as System Exclusive, over MIDI or USB. A program is a message of 1024 data bytes packed into 1171, and it returns to the bank and location it was sent from.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 01
- Model ID
- 2E
- Default device ID
- None: dump and request messages carry no device or channel byte
Receiving a dump
1. Press GLOBALS once (upper row), then program selector 8 (MIDI SysEx). 2. With BANK and TENS choose MIDI or USB, the port the data will arrive on. 3. Press GLOBALS twice to exit. 4. Send the file from the computer: the program number counts up as the programs arrive. They load into the bank and location they were dumped from and replace what is there.
Sending a dump from the instrument
1. Press GLOBALS once (upper row), then program selector 8 (MIDI SysEx), and choose MIDI or USB with BANK and TENS. 2. Press GLOBALS a second time (lower row), then program selector 8 (Pgm Dump): the WRITE button flashes. 3. With BANK and TENS choose Program, Tens (ten programs), Bank, User banks (0-4) or All (user and factory). 4. Press WRITE.
Requesting a dump
Program: F0 01 2E 05, bank number (0-9), program number (0-99), F7. Edit buffer: F0 01 2E 06 F7. Global parameters: F0 01 2E 0E F7. The OB-6 answers with a program data dump (F0 01 2E 02, bank, program, data, F7), an edit buffer dump (F0 01 2E 03, data, F7) or a global parameters dump (F0 01 2E 0F, data, F7).
SysEx pitfalls
A program is 1024 bytes sent as 1171 MIDI bytes: every 7 data bytes are preceded by one byte holding their top bits. The global parameters dump is only transmitted on request; the OB-6 ignores it when received. Factory banks 5-9 cannot be overwritten. Loading the factory file replaces the user programs. For MIDI-OX the manufacturer asks for Low Level Output Buffers Num and Size of 1024 and Auto-adjust Buffer Delays switched off. The Oberheim support page warns that Digidesign/Avid interfaces and Native Instruments Maschine may not transmit SysEx correctly.
Source: OB-6 Operation Manual, version 1.2, pp. 13, 15, 64 and 86-89 ↗
Specifications
- Synthesis
- Analog subtractive, with digital effects
- Polyphony
- 6 voices
- Multitimbrality
- Mono-timbral: no splits or layers
- Oscillators
- Per voice: 2 VCOs (VCO 1 sawtooth to variable pulse; VCO 2 triangle, sawtooth, variable pulse), a sub-octave on VCO 1 and white noise
- Filter
- 2-pole, 12 dB/oct analog state-variable filter per voice: low-pass, notch and high-pass on a continuous mode knob, band-pass by switch
- Memory
- 1000 programs: 500 user (banks 0-4) and 500 permanent factory programs (banks 5-9)
- Keyboard / format
- 49 keys (four octaves), semi-weighted, with velocity and channel aftertouch
- Outputs
- Stereo outputs (left/mono and right, 1/4 inch unbalanced) and stereo headphones
- MIDI
- MIDI In, Out and Thru (5-pin DIN); USB (class-compliant MIDI)
Known issues and maintenance
Calibration. Oscillators and filters drift with temperature. Let the OB-6 warm up for some minutes, then hold MANUAL and press 0; repeat over the first days of use and after moving to a warmer or cooler place. Do not switch off while the routine runs. Hum. The USB connection can cause a ground loop; the MIDI sockets are opto-isolated. Failed OS update. Powering on while holding WRITE enters a bootloader that accepts the OS again, over a MIDI cable only, not USB.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- OB-6 Operation Manual, version 1.2 (Sequential, February 2021) ↗ — Voice architecture, program memory, globals, SysEx dumps, calibration, troubleshooting and the MIDI implementation
- Oberheim: OB-6 analog synthesizer (product page) ↗ — Specification list: keyboard, sequencer, effects, connections, size and weight
- Sequential: OB-6 Factory Sounds ↗ — Factory program banks as SysEx and how to load them with MIDI-OX or SysEx Librarian
- Oberheim: Product Support ↗ — OB-6 downloads and notes on SysEx transfers and MIDI interfaces
- Gordon Reid, "Dave Smith Instruments OB6", Sound On Sound, August 2016 ↗ — Review: brand at launch, price, mono-timbral design, strengths and limits
- "Dave Smith Instruments now shipping OB-6 Analogue Synth", Sound On Sound news, 2016 ↗ — Start of shipping in 2016 and US price