Photo: Pete Brown from Gambrills, MD, USA (Wikimedia Commons) · CC BY 2.0 ↗
Sequential Circuits Pro 2
The Pro 2 is a hybrid keyboard synthesizer from Dave Smith Instruments, introduced in 2014 and now supported by Sequential. It is primarily monophonic but can play up to four notes paraphonically. Four digitally generated oscillators plus a sub oscillator offer classic, wavetable-derived and noise waveforms, and feed two analogue filters: a 4-pole resonant low-pass and a 2-pole state-variable filter, usable in series or parallel. A step sequencer, arpeggiator, delays, touch sliders and four CV inputs and outputs make it a hub for modular gear as well as a lead and bass synth. Sound On Sound's Gordon Reid reviewed it in January 2015, describing one filter as Prophet-like and the other as Oberheim-like and calling the instrument very good value, while noting issues with the CV scaling. The Pro 2 holds 792 programs in eight banks of 99: four user banks and four permanent factory banks. From the Global menu it can send the current program, the current bank or all four user banks as System Exclusive over MIDI or USB, and each program returns to the same bank and location when sent back. A computer can also request a single program, the edit buffer or the global settings.
SysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 01
- Model ID
- 2C
- Default device ID
- None: program messages carry no device ID (F0 01 2C ...)
Receiving a dump
1. Press the global button. 2. Turn soft knob 1 to item 9, MIDI Sysex Enable, and set it to On. 3. Go to item 10, MIDI Sysex Cable, and choose MIDI Port or USB according to the connection used.
Sending a dump from the instrument
1. Press the global button and check items 9 (MIDI Sysex Enable On) and 10 (MIDI Sysex Cable). 2. Turn soft knob 1 to item 36 Dump Current Program, 37 Dump Current Bank or 38 Dump All User Banks. 3. Execute the command with the soft key shown on the display; the data is sent on the selected port.
Requesting a dump
Request Program: F0 01 2C 05 bank(0-7) program(0-98) F7. Request Program Edit Buffer: F0 01 2C 06 F7. Request Globals: F0 01 2C 0E F7. Replies: Program Data F0 01 2C 02 bank program + 1171 packed bytes F7; Edit Buffer F0 01 2C 03 + 1171 bytes F7; Globals F0 01 2C 0F + 50 nibbles (25 parameters) F7.
SysEx pitfalls
MIDI Sysex Enable must be On and MIDI Sysex Cable must match the port in use (MIDI or USB), otherwise nothing is sent or received. Dumped programs and banks reload into the same bank and location, overwriting what is there; factory banks cannot be overwritten from the panel. The global dump is transmitted only. Program data is 1024 bytes packed into 1171 MIDI bytes. Sequential's loading notes set MIDI-OX output buffers to 1024 with automatic buffer delays off.
Source: Pro 2 Operation Manual v1.2 (Dave Smith Instruments, April 2017), pp. 11, 14 and 134-137 ↗
Specifications
- Synthesis
- Hybrid: digital oscillators with analogue filters; monophonic with 4-note paraphonic mode
- Polyphony
- Monophonic; up to 4 notes in paraphonic mode
- Oscillators
- 4 oscillators plus a sub oscillator on oscillator 1; classic waves (sine, triangle, sawtooth, square), wavetable-derived shapes, noise and super waves
- Filter
- Filter 1: 4-pole 24 dB/oct analogue resonant low-pass; Filter 2: 2-pole 12 dB/oct analogue state-variable; serial or parallel
- Memory
- 792 programs in 8 banks of 99: 4 user banks and 4 permanent factory banks
- Keyboard / format
- 3.5-octave (44-key) semi-weighted keyboard with velocity and aftertouch
- Outputs
- Stereo unbalanced 1/4-inch outputs, 1/4-inch stereo headphones; 1/4-inch audio input; 4 CV outputs and gate output
- MIDI
- MIDI In, MIDI Out, MIDI Thru/Out 2; USB (class compliant, MIDI only)
Known issues and maintenance
The Global menu has calibration routines for the touch sliders, the wheels and the filters, to be used only if sliders lose range, the synth plays out of tune or a filter sounds wrong. USB can cause ground hum; the manual suggests MIDI, which is opto-isolated.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Pro 2 Operation Manual, Version 1.2, April 2017 (Dave Smith Instruments) ↗ — Sound banks, connections, global settings and dump commands, filters, MIDI implementation, SysEx messages, troubleshooting
- Pro 2 product page (Sequential) ↗ — Specifications, keyboard, I/O, dimensions; no longer in production
- The Pro 2 is Shipping! (Sequential news, 12 August 2014) ↗ — Release date, price, main features
- Downloading Pro 2 Factory Sounds (Sequential) ↗ — Official factory programs and SysEx loading instructions
- Gordon Reid, "Dave Smith Instruments Pro 2", Sound On Sound, January 2015 ↗ — Review: 44-key keyboard, filters, CV issues, verdict
Sign in to write a comment.
Comments