no image yet
Sequential Circuits · Synthesizer · 2021

Sequential Circuits Take 5

The Take 5 is a compact five-voice analogue polysynth that Sequential introduced in August 2021. Each voice has two analogue voltage-controlled oscillators with continuously variable waveshape, a sub-oscillator, hard sync and FM, feeding a 4-pole resonant low-pass filter descended from the Prophet-5 Rev4. Digital effects (a dedicated reverb and a multi-effect), an overdrive, a Vintage knob that adds voice-to-voice variation, an arpeggiator and a 64-step polyphonic sequencer complete the instrument, played from a 44-key Fatar keyboard with velocity and aftertouch. Sequential presents it as a portable poly for newcomers and for players short of space. Operating system 2.0 doubled the program memory and added looping envelopes, LFO slew and a Lo-Fi tape effect. With OS 2.0 the Take 5 holds 512 programs: 256 user and 256 permanent factory programs in banks of 16. From the Global menu it can send the current program, the current bank or all user banks as System Exclusive over MIDI or USB, and each program returns to the same bank and location when sent back. Alternative tuning scales and operating system updates are also loaded as SysEx, and a computer can request a program, the edit buffer or the global settings.

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
01
Model ID
35
Default device ID
None: program messages carry no device ID (F0 01 35 ...)

Receiving a dump

1. Press the global button. 2. With the select knob choose 21 MIDI Sysex On and set it to On with the value knob. 3. Choose 22 MIDI Sysex Cable and set it to USB or MIDI according to the connection used. 4. Press the global button again to leave the menu.

Sending a dump from the instrument

1. Connect the Take 5 to the computer (USB) or to the MIDI interface and start the librarian in receive mode. 2. Press the global button and set 22 MIDI Sysex Cable to USB or MIDI. 3. With the select knob choose 32 Dump Preset, 33 Dump Bank or 34 Dump All Banks. 4. Press Write: the program, bank or all user banks are sent.

Requesting a dump

Request Program: F0 01 35 05 bank program F7. Request Program Edit Buffer: F0 01 35 06 F7. Request Globals: F0 01 35 0E F7. The Take 5 answers with Program Data (F0 01 35 02 bank program, packed data, F7), Edit Buffer Data (F0 01 35 03, packed data, F7) or the global data (function 0F).

SysEx pitfalls

MIDI Sysex On must be set and MIDI Sysex Cable must match the port in use. Received programs replace whatever is in the same bank and location. The global dump is transmitted only. Sequential's loading notes set MIDI-OX output buffers to 4096 with automatic buffer delays off, and the OS 2.0 factory banks require OS 2.0 on the instrument.

Source: Take 5 User's Guide v2.0 (Sequential, May 2025), pp. 14-15 and 74; Take 5 MIDI Implementation V2, pp. 14-17 ↗

Specifications

Synthesis
Analogue subtractive with digital effects
Polyphony
5 voices
Oscillators
2 analogue VCOs per voice with continuously variable shape (sine, sawtooth, variable pulse), square sub-oscillator on oscillator 1, hard sync, FM; noise generator
Filter
4-pole resonant analogue low-pass per voice, Prophet-5 Rev4 lineage, self-oscillating
Memory
512 programs with OS 2.0: 256 user and 256 factory in 16 banks of 16 (128 + 128 in 8 banks before OS 2.0)
Keyboard / format
44 full-size semi-weighted Fatar keys with velocity and channel aftertouch
Outputs
Stereo unbalanced 1/4-inch outputs, 1/4-inch stereo headphone jack
MIDI
MIDI In, MIDI Out, MIDI Thru; USB (class compliant, MIDI only)

Known issues and maintenance

The Global menu has calibration routines for the wheels and for the oscillators and filters (Cal Voices). After installing OS 2.0 the global parameters must be reset with Reset Globals.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Take 5 MIDI Implementation V2 (Sequential, 2025) ↗ — MIDI global settings, controllers, NRPN list, SysEx messages and packed data format
  2. Take 5 User's Guide, Version 2.0, May 2025 (Sequential) ↗ — Connections, program memory, global settings and dump commands, exporting and importing programs, alternative tunings
  3. Take 5 OS 2.0 Addendum (Sequential) ↗ — Program memory extended to 16 banks, new features, reset globals after update
  4. Take 5 Compact Poly Synth (Sequential news, 23 August 2021) ↗ — Launch, price, main features, 44-key Fatar keyboard
  5. Take 5 product page (Sequential) ↗ — Specifications, effects, keyboard, I/O, dimensions
  6. Download Take 5 Sound Banks (Sequential) ↗ — Official factory banks and SysEx loading instructions
  7. Take 5 MIDI Implementation 1.2 and User's Guide 1.1 (Sequential, 2021-2022) ↗ — Earlier editions, used to cross-check the model ID and dump commands

Comments

0

Sign in to write a comment.

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.