no image yet
Waldorf · Sound Module · 1996

Waldorf Pulse

The Waldorf Pulse is a monophonic analogue synthesizer in a rack case, reviewed by Sound On Sound in February 1996. Its voice has three oscillators, a mixer, two LFOs, two envelopes, an arpeggiator and a resonant 24 dB per octave low-pass filter that can self-oscillate. The Pulse Plus version adds a CV/Gate interface and further connections. The Pulse keeps 99 programs, 40 of them user programs and 59 fixed factory presets. Every parameter is sent and received as a MIDI controller, so the Pulse can be programmed from a sequencer. Sound On Sound found the factory sounds puzzling but called it an excellent monosynth module able to deliver first-class analogue sounds. The Pulse sends a single program, a bulk dump of all sound programs, or its global parameters as System Exclusive data, and an All dump chains them together. It needs no receive mode: a single program arrives in the edit buffer and must be stored, while bulk and global dumps are written directly into memory. Dumps addressed to the broadcast ID 127 are always accepted.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

SysEx guide

Manufacturer ID
3E
Model ID
0B

Receiving a dump

1. Set the global parameter Device ID to the ID in the dump (a dump sent to ID 127 is always accepted). 2. Make sure no program is in Edit mode: unstored edits are lost. 3. Start the sender. A single program arrives in Edit mode and must be stored; bulk and global dumps are written straight into memory.

Sending a dump from the instrument

1. Hold Shift and press Mode (its alternate function is Dump), then release Shift. 2. Select the dump function (program, all, controller) with the Scroll keys. 3. Hold Shift and press Mode again to send. The Pulse cannot be played during the dump.

Requesting a dump

The manual says a dump can be started by a Dump Request from the device that is to receive it; the request formats are in the appendix of the manual.

SysEx pitfalls

Device IDs of sender and receiver must match, except for broadcast ID 127, whose checksum is ignored; the Pulse cannot send ID 127. A transfer can take up to 20 seconds: switching off during it can cause total data loss.

Source: Waldorf User's Manual Pulse / PulsePlus, version 2.0 (22.11.97), pp. 40-41 and 64

Specifications

Synthesis
Analogue subtractive, monophonic
Polyphony
Monophonic
Oscillators
3 oscillators
Filter
Analogue resonant low-pass, 24 dB per octave, self-oscillating
Memory
99 programs: 1-40 user, 41-99 factory presets
Keyboard / format
Rack module, no keyboard
Outputs
Stereo Out Left/Mono and Right
MIDI
In, Out, Thru

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Waldorf, User's Manual Pulse / PulsePlus, version 2.0, 22.11.97 (manualslib copy) — Manufacturer manual read page by page on a manual site: type, memory, filter, connections, SysEx procedures, bulk dump header
  2. Waldorf, Legacy Pulse series ↗ — Official legacy page with download folders
  3. Paul Nagle, Waldorf Pulse, Sound On Sound, February 1996 ↗ — Contemporary review: price, format, MIDI control, verdict