Yamaha SPX90
The Yamaha SPX90 Digital Multi-Effect Processor is a rack unit reviewed in Britain in spring 1986. It processes one mono input to a stereo output with 16-bit linear conversion at 31.25 kHz, giving an effect bandwidth of 12 kHz. It offers 30 preset programs, including reverbs, delays, chorus, flanging, pitch change and a short freeze sampler, and 60 user memories. Programs can be recalled over MIDI through four tables that map program change numbers to memories, and some programs respond to MIDI notes. Reviewers praised the range and quality of its effects for the price, while noting that it runs one effect at a time. The manual documents System Exclusive bulk dumps of single user memories and of the program change tables, started by a bulk dump request. The unit has MIDI In and Thru only: a 1988 Sound On Sound article explains that an internal switch turns the Thru socket into a MIDI Out, and gives corrected request messages from Yamaha.
Sign in to upload or commentSysEx messages
0 filesThis instrument is still waiting for its first SysEx.
If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.
Upload a SysExSysEx guide
- Manufacturer ID
- 43
- Model ID
- 7E (universal bulk format)
- Default device ID
- MIDI channel 1-16 in the second byte after F0 43 (0n for dumps, 2n for requests)
Sending a dump from the instrument
There is no front-panel dump. The SPX90 sends data only in answer to a bulk dump request, and only after the internal switch SW105 has been moved so that the Thru socket works as MIDI Out (unplug the unit before opening it).
Requesting a dump
Send one request per user memory: F0 43 2n 7E 4C 4D 20 20 38 33 33 32 4D mm F7, where mm is 1F (memory 31) to 5A (memory 90). For the program change tables use 54 bb instead of 4D mm, with bb 01 to 04. Sound On Sound reports that the request printed in the manual is wrong and that these corrected bytes came from Yamaha.
SysEx pitfalls
The unit cannot answer all requests at once: leave at least 1 ms between them. Nothing happens while the SPX90 is in Utility mode. One user memory dump carries 78 data bytes; a program change table carries 129.
Specifications
- Synthesis
- Digital multi-effects, 16-bit linear, 31.25 kHz sampling
- Memory
- 30 preset programs (ROM) and 60 user programs (RAM, memories 31-90); 4 program change tables
- Keyboard / format
- Rack unit, 480 x 45.2 x 285 mm
- Outputs
- Stereo L/R unbalanced outputs (-20/+4 dBm); one mono input
- MIDI
- MIDI In, Thru (Thru can be changed to Out with internal switch SW105)
Known issues and maintenance
A backup battery lasts about 5 years in normal use; changing it may erase the user programs, while presets are safe.
Sources
to be verifiedThese notes have not been checked against the sources yet. Corrections are welcome in the comments.
- Yamaha SPX90 Digital Multi-Effect Processor Operating Manual (scan and OCR text on the Internet Archive) — Program counts, battery backup, MIDI program change tables, MIDI In and Thru, MIDI data format with System Exclusive bulk dump and request pp. 23-24, implementation chart, specifications
- Mike Collins, "How to Store your SPX90 Effects", Sound On Sound, October 1988 ↗ — Internal switch SW105 to turn Thru into Out, corrected bulk dump request bytes from Yamaha, channel byte, 1 ms spacing, Utility mode pitfall
- Ian Gilby, "Yamaha SPX90", Sound On Sound, April 1986 ↗ — Review: 30 presets and 60 user memories, MIDI program selection, 31.25 kHz sampling and 12 kHz bandwidth, price, verdict
- Tim Goodyer, "Yamaha SPX90 Multi-Effect Processor", Electronics & Music Maker, March 1986 ↗ — Review: program memory, freeze sample length, MIDI patch change, price
- David Mellor, "Hands On: Yamaha SPX90", Sound On Sound, December 1991 ↗ — Retrospective: high-frequency dulling, risk of overwriting user memories, verdict