How to send a SysEx file to your synth
Loading a SysEx file means sending its bytes from a computer to the MIDI input of the instrument. The instrument recognises its own format and stores the data. Nothing is installed on the instrument, and the file is not changed.
What you need
- A MIDI connection: a USB MIDI interface with a cable from its MIDI OUT to the MIDI IN of the instrument, or a USB cable if the instrument has a USB MIDI port of its own.
- A SysEx file made for your model. A file for another instrument is simply ignored.
- A program that sends SysEx: the browser is enough, see below.
Before you send
- Save what is in the instrument. A bank dump replaces the sounds in memory. If you care about them, make a backup first.
- Turn memory protection off, if the instrument has it.
- Enable SysEx reception. The name changes with the brand: “Exclusive On”, “SysEx Receive”, “Bulk Receive”. Some instruments must also be on a certain page or mode while they receive.
- Check the device number or MIDI channel. Many instruments ignore a dump addressed to another device number than their own.
On SysexDB many device pages have a “SysEx guide” section with the exact steps for that instrument, taken from its manual.
From the browser, with SysexDB
- Open the page of the file and sign in: sending, like downloading, needs a free account.
- In the “Send to device” panel press “Connect MIDI”. The browser asks your permission the first time.
- Choose the MIDI output that goes to the instrument.
- Press the “Send” button. The panel shows the progress and tells you when it has finished.
This works in Chrome, Edge and Firefox on a computer. Safari, and every browser on iPhone and iPad, cannot talk to MIDI devices: there, download the file and use one of the programs below.
With a program on your computer
Windows: MIDI-OX. Choose your interface in Options › MIDI Devices, open View › SysEx and use the “Send SysEx File” command of that window.
macOS: SysEx Librarian. Drag the file into the window, choose the destination at the top and press Play.
Linux: amidi. List the ports with amidi -l, then send the file with
amidi -p hw:1,0,0 -s file.syx, using the port name from the list.
If nothing happens
- Check the cable: OUT of the interface into IN of the instrument, not the other way round.
- Check that the right MIDI output is selected, and that reception and device number are set as above.
- Check that the file is for your exact model and, for expanded instruments, for the same memory layout.
If the instrument reports an error
Messages like “MIDI buffer full”, “checksum error” or “data error” usually mean that the data arrived too fast or damaged. Older instruments need a pause between one message and the next: the “Send to device” panel has a field for it, and MIDI-OX and SysEx Librarian have the same setting. Some inexpensive USB MIDI cables corrupt long SysEx messages: if slowing down does not help, try another interface.
Tell the others
After trying a file on real hardware, use the “Works” and “Doesn't” pads on its page. The next owner will know whether to trust it.