no image yet
Casio · Synthesizer · 1985

Casio CZ-5000

The Casio CZ-5000 is a 61-key digital synthesizer with a built-in eight-track sequencer, which reached the market in 1985. It uses Casio's Phase Distortion (PD) sound source: a voice has one or two lines, each with a DCO offering 33 waveforms, a DCW block that plays the part of a filter and a DCA, all with eight-step envelopes. It plays 16 notes with one-line voices and 8 with two-line voices, and has Tone Mix and Key Split modes and a stereo chorus. The keyboard is not touch sensitive. The sequencer records up to 3,500 notes in real time or 7,000 entered manually, and each track can play its own sound. International Musician found the instrument 'astonishingly good value for money' at GBP 955, while reviewers regretted the single stereo output. It holds 32 preset and 32 memory voices; a RAM cartridge or a cassette recorder stores more. Voices also travel over MIDI as System Exclusive. Casio's CZ-1 manual describes saving 32 CZ-1 tones into the CZ-5000's memory bank and loading the CZ-5000's 32 preset and 32 memory voices into a CZ-1, started from the CZ-1. Tone names, velocity and level settings are not part of the exchange.

Sign in to upload or comment

SysEx messages

0 files

This instrument is still waiting for its first SysEx.

If you own one, or can recover a dump from an old disk or backup, upload it here: every message helps the library and the community grow.

Upload a SysEx

From compatible models

Casio CZ

Related models: CZ-1CZ-1000CZ-101CZ-3000

The CZ-1 operation manual describes tone data exchange over MIDI with the other CZ models.

SysEx guide

Manufacturer ID
44
Default device ID
MIDI receive channel (CH); it must match the sender's channel

Receiving a dump

1. Connect the sender's MIDI OUT to the CZ-5000's MIDI IN (and the CZ-5000's MIDI OUT to the sender's MIDI IN for two-way transfers). 2. Press the MIDI key and set the receive channel (CH) to the sender's channel. 3. Set PRG to ENA. 4. Set the PROTECT switch on the rear panel to OFF. 5. Start the transfer from the other instrument. When it has finished, set PROTECT back to ON.

Requesting a dump

The CZ-5000 answers requests from the other device. Casio's CZ-1 manual defines a send request (the instrument sends the data of one tone for the given memory number) and a receive request (it stores the tone data that follows into the given memory number). From a CZ-1, MIDI LOAD with SUSTAIN held reads the CZ-5000's 32 preset and 32 memory voices; MIDI SAVE writes 32 tones into its memory bank A1-D8.

SysEx pitfalls

No front-panel dump command was found for the CZ-5000: transfers are started by the other device. In an exchange with a CZ-1, tone names and the CZ-1's velocity and level settings are not transferred, so a tone may sound different on the two instruments. The byte format was not available.

Source: Casio CZ-1 Operation Manual, viewer pp. 54, 57 and 62-63; Casio CZ-5000 Operation Manual, viewer pp. 11 and 50-51

Specifications

Synthesis
Phase Distortion (PD) digital synthesis
Polyphony
16 voices with one-line (1 DCO) voices, 8 voices with two-line (2 DCO) voices
Multitimbrality
Eight-track sequencer with a different sound per track; MIDI mono mode with a separate sound per channel
Oscillators
DCO 1 and DCO 2, 33 waveforms, eight-step pitch envelope; detune, ring modulation and noise modulation
Filter
No conventional filter: DCW 1 and DCW 2 (digitally controlled wave) with eight-step wave envelope and key follow 0-9
Memory
32 preset voices (fixed), 32 memory voices; 32 more on an optional RAM cartridge; cassette storage
Keyboard / format
61 keys, 5 octaves, no velocity or aftertouch
Outputs
Line out R and L (one jack alone gives mono), headphones
MIDI
MIDI In, MIDI Out

Known issues and maintenance

Backup batteries. The memory is kept by three D-size dry cells with a stated life of about one year, so they have to be renewed regularly. Protect switch. With the rear PROTECT switch ON, nothing can be written to memory or loaded from a cartridge or cassette. The manual says to leave it ON and switch it OFF only to write or load. Tape. Voices and sequencer data can be saved to a cassette recorder through the MT terminal; the manual gives a VERIFY procedure to check the recording. Limits noted by reviewers in 1985: no touch sensitivity, one stereo output for all sequencer tracks, no auto-correction or looping in the sequencer.

Sources

to be verified

These notes have not been checked against the sources yet. Corrections are welcome in the comments.

  1. Casio CZ-5000 Operation Manual (scan hosted by ManualsLib) — Specifications, sequencer capacity, rear panel, protect switch, tape save, MIDI settings. Only part of the pages have readable text.
  2. Casio CZ-1 Operation Manual (scan hosted by ManualsLib) — Tone data exchange over MIDI between the CZ-1 and the CZ-5000, and the send/receive request messages (pp. 54, 57, 62-63)
  3. Casio: Product History (chronology) ↗ — Casio's first synthesizers, CZ-101 and CZ-1000, released in November 1984
  4. Mark Jenkins, "Casio CZ 5000", One Two Testing, July 1985 ↗ — Polyphony, memory, sockets (MIDI In and Out only on the review unit), criticisms
  5. Jim Betteridge, "CZ Top", Electronic Soundmaker & Computer Music, July 1985 ↗ — Sequencer, MIDI modes, price, no touch sensitivity
  6. Tony Mills, "Casio CZ-5000", International Musician & Recording World, August 1985 ↗ — Keyboard, memory, chorus, outputs, tape dump, price and verdict
  7. Curtis Schwartz, "BMF Review", International Musician & Recording World, October 1985 ↗ — First UK showing at the 1985 British Music Fair
  8. Mark Jenkins, "Casio CZ3000 - The Obvious Solution?", Sound On Sound, April 1986 ↗ — Differences between the CZ-3000 and the CZ-5000 (sequencer, tape dump, MIDI Thru)
  9. Joe Brusi, "Total recall - Cosmology", The Mix, March 1995 ↗ — Retrospective on the CZ range: all models share the same SysEx sound data format